![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 425](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550425.webp)
10-57
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (105)
For additional information, refer to the
“Aggregation Gate Set Failed—Signaling (105)” section on
SIGNALING (106)
To troubleshoot and correct the cause of the alarm, refer to the
“Enhanced Subscriber Authentication
BTS 10200 Delivery Function Connection Down—Signaling (106)” section on page 10-144
DESCRIPTION
Aggregation Gate Set Failed (AGGR Gate Set Failed)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
AGGR-ID–STRING [16]
Error-Code–TWO_BYTES
Sub-Error-Code–TWO_BYTES
PRIMARY
CAUSE
The gate set acknowledgement never came from the CMTS.
PRIMARY
ACTION
None
DESCRIPTION
Enhanced Subscriber Authentication BTS 10200 Delivery Function Connection Down (ESA BTS DF
Connection Down)
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
PRIMARY
CAUSE
The delivery function (DF) server is not responding.
PRIMARY
ACTION
Check the encryption key or the IP connectivity to the DF server.