![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 421](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550421.webp)
10-53
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (97)
To troubleshoot and correct the cause of the alarm, refer to the
“Insufficient Information to Complete
Call—Signaling (97)” section on page 10-143
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
SIGNALING (98)
To troubleshoot and correct the cause of the alarm, refer to the
Inconsistencies—Signaling (98)” section on page 10-143
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Insufficient Information to Complete Call
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Gateway ID–STRING [32]
Call ID–EIGHT_BYTES
Conf ID–EIGHT_BYTES
Call Ref Value–EIGHT_BYTES
PRIMARY
CAUSE
Not enough initial call setup information was received to establish the call.
PRIMARY
ACTION
Call Cisco TAC. (Contact Cisco TAC.)
DESCRIPTION
H323 Protocol Inconsistencies
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Gateway ID–STRING [32]
Call ID–EIGHT_BYTES
Reason–STRING [128]
PRIMARY
CAUSE
The H323 endpoint and the BTS 10200 are running different protocol versions.
PRIMARY
ACTION
This is only an issue where the endpoint is running a higher version of the H323 protocol than the BTS
10200. Call Cisco TAC. (Contact Cisco TAC.)