10-40
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (74)
To monitor and correct the cause of the event, refer to the
“Integrated Services Digital Network: Unable
to Send the SERVICE Due to the SERVICE Timer Expired—Signaling (74)” section on page 10-109
SIGNALING (75)
To troubleshoot and correct the cause of the alarm, refer to the
Ready—Signaling (75)” section on page 10-139
DESCRIPTION
Integrated Services Digital Network: Unable to Send the SERVICE Due to the SERVICE Timer
Expired (ISDN: Unable to Send the SERVICE Due to the SERVICE Timer Expired)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Termination Name–STRING [40]
Termination Index–FOUR_BYTES
Trunk Group ID–FOUR_BYTES
Trunk Group Index–FOUR_BYTES
Service Status–FOUR_BYTES
PRIMARY
CAUSE
The ISDN signaling adapter was unable to send a SERVICE message due to the expiration of the
SERVICE timer.
PRIMARY
ACTION
Ensure that the SERVICE timer is set to an appropriate level.
DESCRIPTION
Signaling System 7 Stack not Ready (SS7 Stack not Ready)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
LogicalName–STRING [64]
PRIMARY
CAUSE
SS7 stack is not configured properly.
PRIMARY
ACTION
Check SS7 stack configuration.
SECONDARY
CAUSE
SS7 stack is not ready.
SECONDARY
ACTION
Check SS7 stack status. Execute the platform
start -i omni