7-95
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Troubleshooting Maintenance Alarms
Figure 7-1
Corrective Action for Maintenance Event (7) (Mate Rejected Changeover)
Forced Switchover Rejected By Secondary
Determine current status
of applicable EM
S
/CA/F
S
.
52070
If both primary and secondary
platforms are stable,
retry the control command.
If both primary and secondary
platforms are not stable,
wait
3
minutes.
If one platform is faulty,
follow procedure shown for
MAINTENANCE event #4.
If not successful, contact
Cisco TAC for assistance.
Determine current status
of applicable EM
S
/CA/F
S
If only one platform is in
a transitional state,
bring down platform that is
in transitional state.
If both platforms are in
a transitional state,
bring down platform that is
in transitional _standby state.
Wait
3
minutes.
Determine current status
of applicable EM
S
/CA/F
S
.
If not successful, contact
Cisco TAC for assistance.
S
table states for this step:
active_normal
active_forced
standby_forced
Attempt to bring up the primary instance of EM
S
, CA or F
S
has
failed, because the secondary instance rejects changeover from
active to standby. MAINTENANCE event #7 was generated
"MATE rejected changeover."
If not successful, contact
Cisco TAC for assistance.
Is mate in
stable state?
Restart the instance that
was just brought down.
No
Yes
If both primary and secondary
platforms are stable,
retry the control command.