Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (29)
To monitor and correct the cause of the event, refer to the
Failure—Maintenance (29)” section on page 7-74
.
MAINTENANCE (30)
For additional information, refer to the
“Element Manager State Change—Maintenance (30)” section on
.
DESCRIPTION
Administrative State Change Failure (Admin State Change Failure)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Facility Type–STRING [40]
Facility Instance–STRING [40]
Failure Reason–STRING [40]
Initial Admin State–STRING [20]
Target Admin State–STRING [20]
Current Admin State–STRING [20]
PRIMARY
CAUSE
An attempt to change the administrative state of a device has failed.
PRIMARY
ACTION
Monitor the system to see if any event reports indicate a database update failure.
SECONDARY
ACTION
If one is found, analyze the cause of the failure. Verify that the controlling element of the targeted
device was in the ACTIVE state in order to service the request to change the ADMIN state of the
device.
TERNARY
ACTION
If the controlling platform instance is not ACTIVE, restore it to service.
DESCRIPTION
Element Manager State Change
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
Element Manager ID–STRING [40]
Current Local State–STRING [40]
Current Mate State–STRING [40]
PRIMARY
CAUSE
The specified EMS has been changed to the indicated state either naturally or via user request.
PRIMARY
ACTION
No action is necessary. This is part of the normal state transitioning process for the EMS.
SECONDARY
ACTION
Monitor the system for related event reports if the transition was to a faulty or out of service state.