Chapter 6 Database Troubleshooting
Database Events and Alarms
DATABASE (25)
To troubleshoot and correct the cause of the alarm, refer to the
“Secure File Transfer Protocol Transfer
Failed—Database (25)” section on page 6-37
.
DATABASE (26)
To troubleshoot and correct the cause of the alarm, refer to the
“File Write Error—Database (26)” section
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Secure File Transfer Protocol Transfer Failed (SFTP Transfer Failed)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
FileName - STRING [128]
Error - STRING [50]
PRIMARY
CAUSE
Unable to connect between active and standby call agents.
PRIMARY
ACTION
Verify communication between primary and CA. On each CA, ping the other node.
SECONDARY
CAUSE
Unable to login to remote host.
SECONDARY
ACTION
Verify that secure shell (SSH) keys have been pre-configured for user root on both active and standby
call agents.
TERNARY
CAUSE
File transfer error.
TERNARY
ACTION
Check the Error dataword to see if it gives an indication of the kind of error that occurred. It could be
a file-system error on the remote host, or a communication failure between the active and standby call
agents.
DESCRIPTION
File Write Error
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Path Name - STRING [128]
PRIMARY
CAUSE
System error, may be out of file descriptors.
PRIMARY
ACTION
Call Cisco TAC technical support. (Contact Cisco TAC.)