
3-9
Cisco Broadband Access Center for Cable Installation Guide 2.7
OL-19105-01
Chapter 3 Installing Components
Installing Components Using the CLI
Installing the Regional Distribution Unit
To install an RDU, complete the steps described in the
“Installing from the Command Line” section on
page 2-8
. Then, follow these steps:
Step 1
When the installation program prompts you to select one or more components, enter
y
and press
Enter
at the Regional Distribution Unit (RDU) (y/n/?) prompt. The program then asks if you want to install
Cisco Network Registrar extension points, the DPE, and the KDC.
Step 2
To skip installing either the extension points or the KDC, press
n
and
Enter
for each option.
You can choose to install these options at a later date. See the
“Installing Network Registrar Extensions”
section on page 3-11
for additional information.
For example:
Installation Components
Select one or more components to install BPR.
Regional distribution unit (RDU) (y/n/?) [no] y
Cisco Network Registrar extension points (y/n/?) [no] n
Device Provisioning Engine (DPE) (y/n/?) [no] n
Key Distribution Center (KDC) (y/n?) [no] n
The program prompts you to confirm the components that you want to install.
Step 3
Press
y
and
Enter
to continue. The program prompts you to start individual component validation.
Step 4
Press
Enter
to continue. For example:
Starting the individual component installation parameters validation.
Press Enter to Continue or 'q' to Quit:
Validating the individual component installation parameters - Please wait.
The program prompts you to enter the home directory destination.
Step 5
To accept the default directory, /opt/CSCObpr, press
Enter
; or enter another directory. For example:
Home Directory Destination
Home Directory Destination [/opt/CSCObpr]
The program asks you to confirm the directory.
Step 6
Press
y
and
Enter
to continue. The program prompts you to enter the data directory destination.
Step 7
To accept the default directory, /var/CSCObpr, press
Enter
; or enter another directory. For example:
Data Directory Destination
Data Directory Destination [/var/CSCObpr]/var/disk0/CSCObpr
The program then asks you to confirm the directory.
Note
By default, the installation program installs the data directory (BPR_DATA) on a different
directory than the home directory (BPR_HOME). Cisco Systems recommends that the data
directory be on a different physical disk than the home directory; for example,
/var/disk0/CSCObpr. However, you can install the data directory on the same disk as the home
directory.