7-10
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 7 Preliminary Steps Before Installing
Mechanical Installation
Figure 7-5
Rack Mounting Dimensions, AC Powered Shelf
Mounting flanges are permanently attached to the front edge of the BPX switch shelf.
Note
It is recommended that you use a lifting device to assist in mounting the shelf with all plug-in cards
installed. This procedure eliminates the possibility of damaging the card contacts during removal and
reinstallation. However, if no lifting device is available, it is possible to temporarily remove the
plug-in cards to lessen the weight. Great care should be taken with removing and reinstalling cards.
The following are the two types of BPX switch shelves with special installation requirements:
•
AC powered
—
Specifies that if you install an AC-powered BPX switch shelf, you must also install
an AC Power Supply Tray directly below it.
•
DC powered—Contains factory-installed DC power entry modules (PEMs) within the shelf itself.
Temporary support brackets and a spacer bar are furnished to ease installation by supporting the BPX
shelf as you slide it into a cabinet.
17.750"
Minimum
between rails
22.750"
13 RMUs
5.250"
3 RMUs
BPX switch
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
H7992
AC PS
Summary of Contents for BPX 8650
Page 49: ...P A R T 1 The BPX Switch ...
Page 50: ......
Page 159: ...P A R T 2 Installation ...
Page 160: ......
Page 273: ...P A R T 3 Initial Configuration and Network Management ...
Page 274: ......
Page 311: ...P A R T 4 Configuring Connections ...
Page 312: ......
Page 487: ...P A R T 5 Troubleshooting and Maintenance ...
Page 488: ......
Page 533: ...P A R T 6 BPX Specifications ...
Page 534: ......
Page 555: ...P A R T 7 Appendices ...
Page 556: ......