Patch Panel Connectors
The PANEL-48-1-DIN and PANEL-48-3-DIN provide 48 DIN 1.0/2.3 connectors on the front side of the
patch panel. These connectors terminate to 75 ohm coaxial cable through the DIN plug.
The PANEL-48-1-RJ48 provide 48 RJ45 connector on the front side of the patch panel. These connectors
terminate to 110 ohm T1/E1 cable through a RJ45 connector.
The PANEL-48-1-AMP64 provide 48 port 110 ohm T1/E1 lines via 4 AMP64 connectors on the front of the
patch panel.
The PANEL-48-3-HDBNC Provide 48 HDBNC connectors on the front of the patch panel. These connectors
terminate to 75 ohm coaxial cable through the HDBNC plug.
Figure 25: Patch Panel Connector on the Patch Panel
Installing Patch Panel
To install the brackets on the rear of the patch panel, perform these steps:
Procedure
Step 1
Remove the larger (M4) rack mount screws (as indicated in the
Rack Mount Screws
figure below) from both
sides. To secure the brackets, follow the instructions in Step-3.
Step 2
Remove the patch panel rack-mount brackets from the accessory kit and position them beside the patch panel.
Step 3
Position the brackets against the patch panel sides, and align with the screw holes. Secure the rack mount
bracket to patch panel using a torque of 13.2 in.-lb (1.5 N-m) see the figure below.
Installing the Cisco ASR 914 Router
49
Installing the Cisco ASR 914 Router