Table 5: Supported Interface Modules and Part Numbers for N560-RSP4 and N560-RSP4-E
Slot
Part Number
Interface Modules
RSP Module
Not Supported
A900-IMA8S
8-port Gigabit Ethernet SFP Interface
Module (8X1GE)
N560-RSP4
and
N560-RSP4-E
Not Supported
A900-IMA8T
8-port Gigabit Ethernet RJ45
(Copper) Interface Module (8X1GE)
Not Supported
A900-IMA1X
1-port 10 Gigabit Ethernet XFP
Interface Module (1X10GE)
Not Supported
ASR900-IMA8S1Z
SFP Combo IM—8-port Gigabit
Ethernet (8X1GE) + 1-port 10 Gigabit
Ethernet (1X10GE)
Not Supported
ASR900-IMA8T1Z
Copper Combo IM—8-port Gigabit
Ethernet (8X1GE) + 1-port 10 Gigabit
Ethernet Interface Module (1X10GE)
Not Supported
ASR900-IMA2Z
2-port 10 Gigabit Ethernet Interface
Module (2X10GE)
7,9
N560-IMA2C
2x100G Interface module
0,1,2,3,4,5,6,7,8,9,10,11,12,13,14
and 15
A900-IMA8CS1Z-M
8-port SFP/8-port CSFP Gigabit
Ethernet (8/16X1GE) + 1-port 10
Gigabit Ethernet (1X10GE) Interface
module
4,5,7,9,10 and 11
A900-IMA8Z
8x10G Interface module
RSP Redundancy
The Cisco ASR 907 Router chassis includes two RSP slots to allow for redundant RSPs. When the router uses
redundant RSPs, one RSP operates in the active mode and the other operates in the hot standby mode. Removal
or failure of the active RSP results in an automatic switchover to the standby RSP.
If you are using redundant RSPs, both the RSPs must be of the same type because a mixed configuration of
two different RSP types is not supported.
Note
Network Timing Interfaces
The RSP supports the following network timing interfaces:
• BITS input/output port—RJ48 jack
• 1 PPS input and output—Mini coax connectors
• 2.048 or 10 MHz input and output—Mini coax connectors
• Time of Day (ToD) or 1 PPS input or output port—Shielded RJ45 jack
Cisco ASR 907 Router Hardware Installation Guide
12
Cisco ASR 907 Router Overview
RSP Redundancy