![Cisco ASR 9000 Serie Configuration Manuals Download Page 166](http://html.mh-extra.com/html/cisco/asr-9000-serie/asr-9000-serie_configuration-manuals_66679166.webp)
Arguments
(Optional) Specifies the number of times the total
correlation occurs before an EEM event is raised.
When a number is not specified, an EEM event is
raised on the first occurrence. The range is from 1 to
4294967295.
occurs
(Optional) Time interval in seconds and optional
milliseconds, during which the one or more
occurrences must take place. This is specified in the
format ssssssssss[.mmm], where ssssssssss must be
an integer number representing seconds between 0
and 4294967295, inclusive and mmm represents
milliseconds and must be an integer number between
0 to 999.
period
(Optional) Specifies the start of an event correlation
window. If not specified, event monitoring is enabled
after the first CRON period occurs.
period-start
(Optional) Specifies the number of seconds and
optional milliseconds after which an event will be
raised if all the conditions are true (specified in the
format ssssssssss[.mmm], where ssssssssss must be
an integer number representing seconds between 0
and 4294967295, inclusive and mmm represents
milliseconds and must be an integer number between
0 to 999).
delay
Result String
None
Example:
trigger occurs 1 period-start "0 8 * * 1-5" period 720
Embedded Event Manager Action Tcl Command Extensions
action_process
Starts, restarts, or kills a Software Modularity process. This Tcl command extension is supported only in
Software Modularity images.
Cisco ASR 9000 Series Aggregation Services Router System Monitoring Configuration Guide, Release 4.2.x
150
Configuring and Managing Embedded Event Manager Policies
Embedded Event Manager Action Tcl Command Extensions