30
Step 3
Remove the shared port adapter from the chassis subslot. Grasp the handle and pull the shared port adapter or blank
panel from the router.
Step 4
Locate the shared port adapter slot guides inside the Cisco ASR 1002-F Router.
Caution
The shared port adapter must slide into the slot guides under the chassis lid. Do not allow the shared port adapter
components to come in contact with the system board or the shared port adapter could be damaged.
Step 5
Carefully slide the shared port adapter into the shared port adapter slot until it is firmly seated and then securely
tightened the captive screws. When installed, the shared port adapter input/output panel should be flush with the face
of the router.
Step 6
Reconnect any cables and place the cables through the cable-management brackets.
Step 7
If the shared port adapter fails to come up, reseat or reinsert the shared port adapter; do not use excessive force.
Step 8
Power on the router by turning the power switch to the On (|) position.
Replace a Power Supply in the Cisco ASR 1002-F Router
This section provides instructions for removing and replacing the AC power supply and the DC power supply in a Cisco
ASR 1002-F Router. Before you begin, make certain the chassis is grounded.
Note
Two power supplies must be installed in the chassis at all times to ensure sufficient cooling. The system fans are inside
the power supply units and must spin for cooling. Because all the system fans can be powered by one power supply, the
second power supply unit does not have to be powered on, but it must be installed.
Caution
If you remove a power supply, the system can run for a maximum of five minutes before the system shuts down.
The fans and power elements are independent within the power supply. Therefore, it is not required that the
replacement power supply be energized within five minutes. The only requirement is that the power supply be
installed in the chassis, which energizes the fans and maintains proper system cooling.
Removing an AC Power Supply
To remove a Cisco ASR 1002-F Router AC power supply that is not operating normally (and then replace the AC power supply
within five minutes), follow this procedure:
Step 1
Slip on the ESD-preventative wrist strap that was included in the accessory kit.
Step 2
Turn the switch to the off (O) position and unplug the AC power cord.
Step 3
Unscrew all of the power supply captive screws.
Step 4
Grasping the power supply handles, pull the power supply from the chassis. When you remove the AC power supply,
you will see the following type of messages in the log report:
#show log
Syslog logging: enabled (0 messages dropped, 6 messages rate-limited, 0 flushes, 0 overruns, xml
disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled