The following image shows the ASR1013/06-PWR-DC power supply for the Cisco ASR 1006 Router.
Figure 54: Cisco ASR 1006 Router DC Power Supply (ASR1013/06-PWR-DC) Terminal Block and Plastic Cover
Plastic cover slotted area
4
Negative terminal
1
Terminal block plastic cover
single screw
5
Positive terminal
2
Terminal block plastic cover
3
Step 10
Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to the On position.
Step 11
Move the circuit breaker switch to the On position.
What to Do Next
This completes the procedure for connecting the DC power supply in the Cisco ASR 1006 Router.
Connecting a Terminal to the Cisco ASR 1000 Series RP Console
Port
The Cisco ASR 1006 route processor has an asynchronous serial (EIA/TIA-232) RJ-45 console port labeled
CON on its front panel. You can connect this port to most types of video terminals through use of the console
cable kit that is included with your Cisco ASR 1006 Router. The console cable kit contains:
Cisco ASR 1000 Series Router Hardware Installation Guide
176
Cisco ASR 1006 Router Overview and Installation
Connecting a Terminal to the Cisco ASR 1000 Series RP Console Port