b) At the
router#
prompt, enter
end
and press
Enter
.
Step 3
Disconnect all the cables from the EPA.
Step 4
Loosen the captive screw in the center of the EPA by turning it counterclockwise.
Step 5
Slide the EPA out of the EPA slot.
Replacing an EPA
Procedure
Step 1
Locate the guide rails that hold the EPA in place.
Step 2
Align the EPA with the guide rails and carefully slide the EPA all the way all the way into the slot until the
EPA stops.
Step 3
Use a number 2 Phillips screwdriver to fully seat the EPA by turning the captive screw clockwise.
When fully seated, the EPA should be flush with the router faceplate.
Avoid overtorquing the EPA captive screw when installing the EPA. Tighten the captive screw on
the EPA to a torque of 11 +/-1 inch-pounds.
Note
Step 4
Restart the EPA using the following steps:
a) At the
router#
prompt, enter
hw-module subslot 0/2 start
and press
Enter
.
b) At the
router#
prompt, enter
end
and press
Enter
.
Step 5
Use the
show platform
command to verify whether the status of subslot 0/2 is OK.
Router#
show platform
Chassis type: ASR1002-HX
Slot
Type
State
Insert time (ago)
--------- ------------------- --------------------- -----------------
0
ASR1002-HX
ok
00:07:52
0/0
BUILT-IN-EPA-8x1G
ok
00:07:00
0/1
BUILT-IN-EPA-8x10G
ok
00:07:00
0/2
EPA-18X1GE
ok
00:07:01
.
.
.
Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router Hardware Installation Guide