5-6
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide
OL-14126-03
Chapter 5 Installing and Removing a SIP
Online Insertion and Removal
For more information about chassis slot and SIP subslot numbering, refer to the
Subslots for SIPs and SPAs” section on page 2-2
Reactivating a SPA
Note
You do not need to reactivate a SPA after an OIR of either the SIP or a SPA if you did not deactivate
the SPA prior to removal when using the
hw-module subslot
command in global configuration mode.
If the Cisco ASR 1000 Series Router is running, then the SPAs automatically start upon insertion into
the SIP or with insertion of a SIP into the Cisco ASR 1000 Series Router.
If you deactivate a SPA using the
hw-module subslot
stop
command and need to reactivate it without
performing an OIR, you must use the
hw-module subslot
start
command to reactivate the SPA and its
interfaces.
Command
Purpose
Router(config)#
hw-module subslot
slot-number/subslot-number
shutdown
[
powered
|
unpowered
]
Deactivates the SPA in the specified slot and subslot of the SIP,
where:
•
slot-number—
Specifies the chassis slot number where the SIP
is installed.
•
subslot-number
—Specifies the subslot number on a SIP where
a SPA is installed.
•
shutdown
—Shuts down the specified SPA.
•
powered
—(Optional) Shuts down the SPA and all of its
interfaces, and leaves them in an administratively down state
with power enabled. This is the default state.
•
unpowered
—(Optional) Shuts down the SPA and all of its
interfaces, and leaves them in an administratively down state
without power.
Router(config)#
hw-module subslot
slot-number/subslot-number
{
reload
|
stop
|
start
}
Deactivates the SPA in the specified slot and subslot of the SIP,
where:
•
slot-number—
Specifies the chassis slot number where the SIP
is installed.
•
subslot-number
—Specifies the subslot number on a SIP where
a SPA is installed.
•
reload
—Stops and restarts the specified SPA.
•
stop
—Stops the specified SPA
.
•
start
—Starts the specified SPA.