Security
Secure Sensitive Data Management
344
Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4
17
Similarly, if authorization is not enabled, and authentication fails for a method, the device
stops the authentication attempt.
To define authentication methods for an access method:
STEP 1
Click
Security
>
Management Access Authentication
.
STEP 2
Enter the
Application
(type) of the management access method.
STEP 3
Select
Authorization
to enable both authentication and authorization of the user by the list of
methods described below. If the field is not selected, only authentication is performed. If
Authorization is enabled, the read/write privileges of users are checked. This privilege level is
set in the User Accounts page.
STEP 4
Use the arrows to move the authentication method between the
Optional Methods
column
and the
Selected Methods
column. The first method selected is the first method that is used.
•
RADIUS
—User is authorized/authenticated on a RADIUS server. You must have
configured one or more RADIUS servers. For the RADIUS server to grant access to the
web-based configuration utility, the RADIUS server must return cisco-avpair =
shell:priv-lvl=15.
•
—User authorized/authenticated on the server. You must have
configured one or more servers.
•
None
—User is allowed to access the device without authorization/authentication.
•
Local
—Username and password are checked against the data stored on the local device.
These username and password pairs are defined in the User Accounts page.
NOTE
The
Local
or
None
authentication method must always be selected last. All
authentication methods selected after
Local
or
None
are ignored.
STEP 5
Click
Apply
. The selected authentication methods are associated with the access method.
Secure Sensitive Data Management
Security: Secure Sensitive Data Management
.