Administration
Console Settings (Autobaud Rate Support)
78
Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4
6
Console Settings (Autobaud Rate Support)
The console port speed can be set to one of the following speeds: 4800, 9600, 19200, 38400,
57600, and 115200 or to Auto Detection.
If Auto Detection is selected, the device detects console speed automatically.
When Auto Detection is not enabled, the console port speed is automatically set to the last
speed that was set manually at (115,200 by default).
When Auto Detection is enabled but the console baud-rate has not yet been discovered, the
system uses speed 115,200 for displaying text (for example, the boot-up information).
After Auto Detection is enabled in the Console Settings page, it can be activated by connecting
the console to the device and pressing the Enter key twice. The device detects the baud rate
automatically.
To enable Auto Detection or to manually set the baud rate of the console:
STEP 1
Click
Administration
>
Console Settings
.
STEP 2
Select one of the following options in the
Console Port Baud Rate
field:
•
Auto Detection
—The console baud rate is detected automatically.
•
Static
—Select one of the available speeds.
STEP 3
Click
Apply
.
Stack Management
Administration: Stack Management
.
User Accounts
The User Accounts page
enables entering additional users that are permitted to access to the
device (read-only or read-write) or changing the passwords of existing users.