Hardware Installation Guide for Cisco 4000 Series Integrated Services Routers
OL-32185-02
Chapter 3 Install and Connect Cisco 4000 Series ISRs
Connect WAN, LAN, and Voice Interfaces
Step 5
Click
Finish
.
Uninstall Cisco Microsoft Windows Vista USB Driver
Note
Disconnect the router console terminal before uninstalling the driver.
Step 1
Run the setup.exe for Windows 32-bit or setup(x64).exe for Windows-64bit. Click
Next
.
The InstallShield Wizard for Cisco Virtual Com appears.
Step 2
Click
Next
The Program Maintenance window appears.
Step 3
Select the
Remove
radio button and click
Next
. The Remove the Program window appears.
Step 4
Click
Remove
. The InstallShield Wizard Completed window appears.
Note
If a User Account Control warning appears, click “Allow - I trust this program...” to proceed.
Step 5
Click
Finish
.
Connect WAN, LAN, and Voice Interfaces
•
•
Connection Procedures and Precautions, page 3-29
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Warning
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network
voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some
LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables.
Statement 1021
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF
or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables,
detach the end away from the unit first.
Statement 1026
Caution
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety,
connect Gigabit Ethernet ports using RJ-45 connectors for shielded twisted pair cable only to
intra-building or unexposed wiring or cable. The intra-building cable must be shielded and the shield
must be grounded at both ends. The intra-building port(s) of the equipment or subassembly must not be