5-22
Hardware Installation Guide for Cisco 4000 Series Integrated Services Routers
OL-32185-02
Chapter 5 Install and Upgrade Internal Modules and FRUs
Remove and Replace Cisco NIM-SSD or NIM-HDD
Figure 5-18
HDD in the NIM Chassis
Cisco NIM-HDD LEDs
shows the LED description for the NIM-HDD.
Remove and Replace Cisco NIM-SSD or NIM-HDD
This section explains how to remove a NIM-SSD or NIM-HDD from the router chassis and replace it
with a new external NIM-SSD or NIM-HDD.
Plugging additional SSD Carrier Card NIMs into a bay powers off the module. Power down the
NIM-SSD module and wait for the power LED to turn off before removing the module or removing and
replacing new SSD drives.
To deactivate and reactivate a NIM, see the “
Deactivating and Reactivating a SSD Carrier Card NIM
section in the
Software Configuration Guide for Cisco 4000 Series ISRs
.
390923
Table 5-3
LED Description for NIM-HDD
LED
Color
Description
EN (Enabled)
Green
The module is powered on and is functioning
correctly.
Amber
Module has some failure.
Off
Default when module is powered on for the first
time. Persistent until changed by the host
software.
HDD0
Green
HDD0 is present.
Amber
Fault detected on HDD0.
HDD ACT
Green
Activity on HDD0 and HDDI
HDD1
Green
HDD1 is present.
Amber