R E V I E W D R A F T — C I S C O C O N F I D E N T I A L
5-2
Cisco Connected Grid Routers 2010 Hardware Installation Guide
OL-21559-01
Chapter 5 Installing and Upgrading Internal Modules
Safety Warnings
Safety Warnings
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Warning
Read the installation instructions before connecting the system to the power source.
Statement 1004
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF
or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables,
detach the end away from the unit first.
Statement 1026
Replacing Power Supplies and Redundant Power Supplies
The Cisco 2010 CGR routers have replaceable power supplies. Use a Number 2 Phillips screwdriver to
remove or install the power supply.
Caution
Any combination of power supplies can be inserted into the chassis. Dual power supply configurations
are load sharing in redundancy mode.
A single power supply is sufficient for supporting power needs to the system; however, if a single PSU
is deployed it must be in slot 1 (PSU1).
Note
The power supplies are hot swappable. The power supply LED must show it is properly functioning
before removing the other power supply in the router.
Replacing the Cisco 2010 CGR Router Power Supply
To replace the power supply in a Cisco 2010 CGR router, perform the following steps. See
for the locations of connectors and other components within the Cisco 2010 CGR router.
Step 1
Loosen the captive screws that fasten the power supply to the chassis.
Step 2
Pull the power supply out of the chassis. See
.