VCC-F32FV19CL
Rev.900-586-31-00
6. Switch Setting, Adjustment Potentiometer Specifications
6. Switch Setting, Adjustment Potentiometer Specifications
6.1. Rear Panel Switch Function 10bit DIP-SW
6.1. Rear Panel Switch Function 10bit DIP-SW
(
●
indicates initial setting position)
(
●
indicates initial setting position)
ON
ON
●
●
OFF
●
●
●
●
●
●
●
●
●
1 2 3 4 5 6 7 8 9 10
1
E0
2
E1
◇
Electronic shutter speed (3bit)
3
E2
4
MODE0
◇
Trigger mode (2bit)
5
MODE1
Normal Mode, Standard Trigger Moe, Pulse Width Trigger Mode
6
SCAN
◇
Partial Scan Mode Selection (1bit)
OFF:10fps
ON: 19fps
7
N/A
◇
Not assigned. (Fixed to OFF)
8
RGB/RAW
◇
RAW/RGB Selection (1bit) OFF: RAW ON: RGB
9
10bit/8bit
◇
8bit/10bit Selection (at RAW setting)
(1bit) OFF:8bit ON:10bit
10
N/A
◇
Not assigned. (Fixed to OFF)
6.1.1. Shutter Speed Settings (Rear panel: SW1:E0, SW2:E1, SW2:E2)
(1) Normal Scan Mode
(2) Standard Trigger Mode
E0 E1 E2 Shutter
Value E0 E1 E2 Shutter
Value
1 2 3
1 2 3
OFF OFF OFF OFF
(1/10)
sec
OFF
OFF
OFF
1/10
sec
ON OFF OFF
1/30
sec
ON OFF
OFF
1/
30
sec
OFF
ON
OFF
1/90 sec
OFF
ON
OFF
1/ 90 sec
ON ON OFF
1/500
sec
ON ON OFF
1/500
sec
OFF
OFF
ON 1/1000
sec
OFF
OFF
ON
1/1000
sec
ON OFF ON
1/2000
sec
ON OFF
ON
1/2000
sec
OFF
ON
ON 1/5000
sec
OFF
ON
ON
1/5000
sec
ON ON ON 1/10000
sec
ON ON ON
1/10000
sec
6.1.2. Operation Mode Settings (Rear panel SW 4: MODE 0, SW 5: MODE 1)
MODE0 MODE1
Setting
Mode
OFF OFF
Normal
Mode
ON
OFF
Standard Trigger Mode
OFF
ON
Pulse Width Trigger Mode
ON ON
Normal
Mode
(1)
Normal Mode
Standard mode means progressive scan, 10fps, and invalid trigger shutter.
(2)
Standard Trigger Mode
Standard trigger mode is a trigger mode to set shutter value via serial communication or fixed switch at
rear. Trigger pulse width shall be over 1HD.
©2009 CIS Corporation. All rights reserved.
12