VCC-FC21U19OP
Rev. 900-766-30-00
©2014 CIS Corporation. All rights reserved.
15
7.
Timing Chart
7.1.
Horizontal Synchronous Signals Timing
(2Tap Base Configuration mode: 63fps)
7.2.
Vertical Synchronous Signals Timing (2Tap Base Configuration Mode: 63fps)
FVAL Out
1Frame = 1104H(15.824ms)
Effective Line : 1088H
Effective Line
DVAL Out
~ ~
LVAL Out
~ ~
Effective Line
~ ~
~ ~
V Blanking : 16H
(Read Out Pulse)
Exposure Time( Address (036&037))
SP Out(Exposure Out)
1
0
8
8
1
0
8
8
1
1
1H = 14.333us
Video Out
~ ~
~ ~
10
H