VCC-FC21FR19PCL
Rev. 900-760-31
©2016 CIS Corporation. All rights reserved.
22
X is the code to respond when error is detected by the camera side.
Details of the detected error can be checked with 4 lines of the 3
rd
to 6
th
byte.
0101: Abnormal address value
0102: Abnormal command
0103: Abnormal data value
0104: Abnormal data length (over 14byte)
Remote controller address
Note: Do not write the data into the address other than specified, since it may cause
the damages or malfunction of the camera.
Remote controller data
Set the decimal number (000
~
255) for the remote controller data. Please be noted to set any
dummy data at read control mode.
CR
Be sure to input “CR” to confirm the end of the command.
※
Note: The data set with 2 Byte shall be set with High Byte (even address) first, then set with
Low Byte (odd address). The camera rewrites the internal resister when receiving Low Byte.
(3)
Data Save
Input data 083 or 053 into the address 127 to save the data to EEP-ROM.
(4)
Initial Settings
Input data 083 or 053 into the address 126 to return to the initial settings.
10.
Initial Settings
Function
Address
Data
Gain
001
0:
0dB
Shutter
002
0:
1/75s(OFF)
White Balance
003
1:
3200K
Trigger Shutter Mode
004
0:
Normal Shutter Mode (Trigger OFF)
Trigger Polarity
011
0:
Positive
Output Data Selection
013
0:
8bit output
Partial Scan Mode
015
0:
Full Frame Scan Mode
Output Image Flip Vertical
021
0:
Normal
Gain CC Control ON/OFF
023
0:
OFF
Baud Rate
030
0:
9600bps
Camera Mode
031
1:
4Tap Medium Configuration Mode