X is the code to respond when error is detected by the camera side. 

 

Details of the detected error can be checked with 4 lines of the 3

rd

 to 6

th

 byte.     

 

  0101: Abnormal address value 

 

  0102: Abnormal command 

 

  0103: Abnormal data value 

 

  0104: Abnormal data length (over 14byte) 

 

Remote controller address 

Note: Do not write the data into the address other than specified, since it may cause 
the damages or malfunction of the camera. 

 
Remote controller data 

Set the decimal number (000

255) for the remote controller data.    Please be noted to set any 

dummy data at read control mode. 

 
CR 
 

Be sure to input “CR” to confirm the end of the command. 

  Note: The data set with 2 Byte shall be set with High Byte (even address) first, then set with 

Low Byte (odd address).    The camera rewrites the internal resister when receiving Low Byte. 

   

(3)

 

Data Save 

 
Input data 083 or 053 into the address 127 to save the data to EEP-ROM. 
 

(4)

 

Initial Settings 

 
Input data 083 or 053 into the address 126 to return to the initial settings. 

 
 

 

10.

 

Initial Settings 

 

Function 

Address 

Data 

Gain 

001 

0: 

0dB 

Shutter 

002 

0: 

1/75s(OFF)   

White Balance 

003 

1: 

3200K 

Trigger Shutter Mode 

004 

0: 

Normal Shutter Mode (Trigger OFF) 

Trigger Polarity 

011 

0:   

Positive 

Output Data Selection 

013 

0: 

8bit output 

Partial Scan Mode 

015 

0: 

Full Frame Scan Mode 

Output Image Flip Vertical 

021 

0: 

Normal 

Gain CC Control ON/OFF 

023 

0: 

OFF 

Baud Rate 

030 

0: 

9600bps 

Camera Mode 

031 

1:   

4Tap Medium Configuration Mode 

Summary of Contents for VCC-FC21FR19PCL

Page 1: ...CC FC21FR19PCL Rev 900 760 31 2016 CIS Corporation All rights reserved Camera link I F 4M Resolution CMOS Color RAW PoCL VCC FC21FR19PCL Product Specification Operational Manual CIS Corporation Englis...

Page 2: ...onfiguration mode 38fps 14 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 38fps 14 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 75fps Initial Setting...

Page 3: ...emely hot or cold places operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places...

Page 4: ...ng is set the faster the camera exposure output speed goes and the more the power consumption is required at the same time Power requirement of when the minimum read out line is set with partial scan...

Page 5: ...r 2048 H x 2048 V 11 264 11 264 mm 1 5 9 3 0 Unit cell size 5 5 m H x 5 5 m V Image Circle 15 930mm 2 Video Output Frequency Pixel Clock 80 MHz 2Tap Base Configuration Mode Horizontal frequency 77 519...

Page 6: ...Shutter Trigger Mode Pulse Width Shutter Trigger Mode 21 Partial Scan Full Frame Scan 1 line 1 line step 22 Safety Quality standards UL Conform to UL Standard including materials and others CE EN55022...

Page 7: ...45us 8Tap Full Configuration mode 1HD 3 225us Functionally no upper limitation is set but noises such as dark noises and shadings might be noticeable at long time exposure Trigger Input CC1 Camera Lin...

Page 8: ...VCC FC21FR19PCL Rev 900 760 31 2016 CIS Corporation All rights reserved 8 4 3 CMOS Spectral Response Representative Value Lens characteristics and luminous source characteristics are not considered...

Page 9: ...ghts reserved 9 4 4 Video Output Format 1 2Tap Base Configuration Mode 38fps 2 4Tap Medium Configuration Mode 75fps Initial Setting 3 8Tap Full Configuration Mode 150fps 2048 Line 2048pixel G B G B 1...

Page 10: ...12 1 20000s 1 20000s 1 20000s 13 1 30000s 1 30000s 1 30000s 14 1 30000s 1 40000s 1 40000s 15 1 30000s 1 40000s 1 50000s 16 Manual Shutter Refer to Address 036 and 037 White Balance 003 0 Through 1 32...

Page 11: ...2 2Tap Base Configuration Mode 38fps Manual Gain 032 033 0 767 0 0dB 767 12dB Manual Shutter 036 037 0 2047 2Tap mode Shutter Speed 16 641us 2048 036 037 12 9us Min value 0 26 436ms 1 38s Max value 2...

Page 12: ...2048 Set 0 when not in use Partial scan effective line numbers 3 084 085 1 2048 Set 0 when not in use Partial scan effective line numbers 4 086 087 1 2048 Set 0 when not in use Partial scan effective...

Page 13: ...er line of the Medium or Full configuration connector side shall be kept open Do not plug and unplug the camera link cables since it may cause the camera malfunction Pin No Pin No Pin No Pin No 1 GND...

Page 14: ...00 760 31 2016 CIS Corporation All rights reserved 14 7 Timing Chart 7 1 Horizontal Synchronous Signals Timing 2Tap Base Configuration mode 38fps 7 2 Vertical Synchronous Signals Timing 2Tap Base Conf...

Page 15: ...760 31 2016 CIS Corporation All rights reserved 15 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 75fps Initial Setting 7 4 Vertical Synchronous Signals Timing 4Tap Medium C...

Page 16: ...L Rev 900 760 31 2016 CIS Corporation All rights reserved 16 7 5 Horizontal Synchronous Signals Timing 8Tap Full Configuration Mode 150fps 7 6 Vertical Synchronous Signals Timing 8Tap Full Configurati...

Page 17: ...etecting trigger edge in the camera to starting exposure is max 1HD Triggers can be accepted even when outputting video signals However trigger signals for exposure to start the next video output prio...

Page 18: ...m detecting trigger end edge to completing exposure is max 1HD Pulse width is min 1HD to approx 2 frames Functionally there is no upper limitation but noises such as dark noises and shadings may be no...

Page 19: ...ideo Out Partial Scan Setting Partial scan start position 1 Address 064 065 Partial scan start position 3 Address 068 069 Partial scan effective lines 2 Address 082 083 Partial scan start position 2 A...

Page 20: ...ne Time for 1 line Camera Mode Time for 1 Line 2Tap Base Configuration Mode 12 9us 4Tap Medium Configuration Mode 6 45us 8Tap Full Configuration Mode 3 225us Setting Example Line numbers at partial sc...

Page 21: ...Process code Remote controller address Remote controller data CR 000000 fixed R Read mode Please refer to the address table of Section 5 Function Settings 000 255 0 Dh W Write mode C Camera mode 00EEE...

Page 22: ...sure to input CR to confirm the end of the command Note The data set with 2 Byte shall be set with High Byte even address first then set with Low Byte odd address The camera rewrites the internal resi...

Page 23: ...VCC FC21FR19PCL Rev 900 760 31 2016 CIS Corporation All rights reserved 23 11 CMOS Optical Axis Accuracy...

Page 24: ...VCC FC21FR19PCL Rev 900 760 31 2016 CIS Corporation All rights reserved 24 12 Dimensions...

Page 25: ...his product specification operation manual In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified In case damage or loss...

Reviews: