background image

  VCC-5CXP3R   

 

Rev. 905-0052-00 

©2016 CIS Corporation. All rights reserved. 

 

1

 

Handling Precautions 

 

The  camera  module  must  not  be  used  for  any  nuclear  equipments  or  aerospace  equipments  with  which 

mechanical failure or malfunction could result in serious bodily injury or loss of human life.    Our warranty 
does not apply to damages or defects caused by irregular and/or abnormal use of the product. 

All specifications contained herein are subject to change without prior notice.    Reproduction in whole or in 
part is prohibited. 

 
Please observe all warnings and cautions stated below.     

Our warranty does not apply to damages or malfunctions caused by neglecting these precautions.

 

 

 

Do not use

 

or store

 

the camera module in the dusty or humid places. 

 

Do not apply excessive force, vibration, or static electricity that could damage the camera.    Handle the camera 
with caution.     

 

Do not shoot direct images that are extremely bright (e.g., light source, sun, etc).    When extremely strong light 
source is shot, smear or blooming may occur.

   

When the camera is not in use, please put the protection cap on. 

 

Follow the instructions in Chapter

 

5, “External Connector Pin Assignment” for connecting the camera module.   

Improper connection may cause damages not only to the camera module but also to the connected devices. 

 

Confirm the mutual ground potential carefully and then connect the camera module to monitors or 
computers.    AC leaks from the connected devices may cause damages or destroy the camera module. 

 

Do not apply excessive voltage. (Use only the specified voltage.)    Unstable or improper power supply 
voltage may cause damages or malfunction of the camera assembly. 

 

Do not disassemble the camera.    The camera once disassembled shall be out of warranty. 

 

2

 

Product Outline 

 

VCC-5CXP3R is a CoaXPress interfaced small Color camera utilizing a 1 type, 5.3M pixels CMOS image sensor. 
 

Features 

 

29mm x 29mm x 55mm in size 

 

Global shutter CMOS (Color) 

 

CoaXPress CXP-1/2/3/5/6 x1 each 

 

The maximum cable length: Approx. 100m (at CXP-1) 

 

ROI 

 

Sub-sampling 

 

Exposure, Gain settings 

 

External trigger mode (Fixed trigger shutter mode / Pulse width trigger shutter mode) 

 

Sequence control 

 

Shading Correction 

 

GenICam complied 

 

3

 

Bundled Items 
3.1

 

Standard Bundled Items 

 

Camera module, VCC-5CXP3R 

 

Lens cap 

 

3.2

 

Packaging 

 

Individual carton 

 

Master carton (10 pcs/carton) 

Note) Q’ty per master carton may vary depends on the shipping q’ty. 

 

 

Aegis Electronic Group, Inc.

Summary of Contents for VCC-5CXP3R

Page 1: ...05 0052 00 2017 CIS Corporation All rights reserved CoaXPress I F 5 3M CMOS Color RAW Camera VCC 5CXP3R Product Specifications Operational Manual CIS Corporation English A e g i s E l e c t r o n i c...

Page 2: ...Mode 8 7 3 1 Internal Sync Mode Free Run Mode 9 7 3 2 External Trigger Sync Mode 9 8 Function Settings 13 8 1 Gain Settings 13 8 2 Exposure Time Settings 14 8 3 ROI Region Of Interest 15 8 4 Sub Samp...

Page 3: ...VCC 5CXP3R Rev 905 0052 00 2016 CIS Corporation All rights reserved 2 12 Case for Indemnity Limited Warranty 31 Product Support 31 A e g i s E l e c t r o n i c G r o u p I n c...

Page 4: ...ter 5 External Connector Pin Assignment for connecting the camera module Improper connection may cause damages not only to the camera module but also to the connected devices Confirm the mutual ground...

Page 5: ...igger 15 Partial Scan ROI 8 Preset patterns Including Full resolution ROI OFF 16 Power Requirements PoCXP 17 Power Consumption 3 6W CXP 6 at full pixel and free run 18 Dimensions H 29mm W 29mm D 55mm...

Page 6: ...XP 2 3 01 01h At 8bit and 0dB Setup level shall be fractured at gain up It can be adjusted by BlackOffset 4 External Trigger Signal Input CoaXPress BNC Connector Low speed uplink 20 83Mbps 6 pins roun...

Page 7: ...4 NC 5 TRIGGER_IN Trigger input 6 GND Conducted with camera casing NC means Non Connection Do not connect anything to the terminal 3 pins SIGNAL_OUT Circuit Timing signals inside the camera can be ou...

Page 8: ...erSets UserSetSave Execute UserSetDefault Execute If you wish to initialize the setting values execute UserSetDefault Execution is only valid at Link rate CxpLinkConfiguration CXP 1 However as long as...

Page 9: ...ence function TriggerSource To set the method for trigger input at External Trigger Sync Mode LinkTrigger0 Utilize LOW SPEED uplink of CoaXPress and input trigger from frame grabber via coaxical cable...

Page 10: ...Approx 150us Notes for trigger pulse input timing A trigger pulse can be input during Readout However please do not input a trigger pulse while reading out signals for the prior frame since it ends i...

Page 11: ...P1 CXP2 CXP3 CXP5 CXP6 Exposure delay at normal readout s Please refer to Exposure delay time A in the timing chart below 4 8 8 4 4 Exposure delay at overlapping s Please refer to Exposure delay time...

Page 12: ...or FVAL term 1 frame rate Trigger cycle needs to be longer than the exposure time Trigger operation is CLK Sync HV Sync Reset More than 30 s of trigger pulse width can be input Maximum exposure time d...

Page 13: ...longer than the time for FVAL term 1 frame rate Trigger operation is CLK Sync H V Sync Reset Minimum trigger width is 30 s Functionally there is no upper limitation However at long exposure some noise...

Page 14: ...will be reduced when gain setting is increased We recommend you to evaluate it first AnalogControl PresetGainX Gain_x1 Gain_x1_5 Gain_x2 Gain_x3 Gain_x4 Gain_x6 Gain_x8 Gain Manual Preset GainX Preset...

Page 15: ...er_1_5000 1 5000 200 us Shutter_1_10000 1 10000 100 us Manual Shutter Mode ExposureTime Video output format link rate and ROI settings has their own maximum exposure time limitation Please refer to th...

Page 16: ...42 6 69 5 85 1 Pattern1 2048x2048 2K2K 4M 8bit 21 5 51 0 51 0 101 4 101 4 10bi 19 2 43 5 51 0 85 8 101 4 Pattern2 1920x1200 WUXGA 8bit 41 7 90 1 90 1 179 4 179 4 10bi 37 4 77 8 90 1 155 6 179 4 Patter...

Page 17: ...gle remains the same as the one for full resolution ImageFormatControl SubsamplingMode Subsampling_On Subsampling_Off This mode cannot be used with ROI mode Execute re grabbing the viewer to acquire i...

Page 18: ...N to calculate and save the correction data automatically in the camera When setting a shading correction data please make sure that ROI and sub sampling settings are OFF When execute DetectShading pl...

Page 19: ...ng pattern at Active settings Lighting Camera condition Light OFF PoCXP No supply Green low speed blinking 0 5 Hz Completion of device and host connection Green light ON Video data transmitting Orange...

Page 20: ...tion The user defined device names can be set in camera by a string of 16 characters User defined device names shall be saved in EEPROM in camera when execute UserSetSave It will revert to the factory...

Page 21: ...f parameter sets can be set in advance The following parameters can be set per parameter set Settable parameter Shutter and Gain Specify the operation sequence as Index Specify the parameter set numbe...

Page 22: ...rActivation once UseSetSave and UserSetDefault shall not be executed at SequencerMode Please set them after turn on the power UserSetSave and UserSetDefault can be executed at other settings for seque...

Page 23: ...when the trigger is ON The exposure time for each frame shall be controlled by sequence parameter set which is set beforehand Sequence performance will end after the sequence loop count of image outp...

Page 24: ...Burst Mode Edge control which uses trigger signal level control and register start is selectable for the start and hold of sequence Please set TriggerSelectorAndActivation to FrameBurstStart 1 Edge C...

Page 25: ...ause After completion of loop count of image output the sequence operation will end and the operation will stop 3 Register Start The sequence operation will start at the same timing as SequencerActiva...

Page 26: ...ivation shall not be saved so it shall be always OFF after turn ON the power Please set it accordingly when use Sequence Mode How to set Sequence control Acquisition Control TriggerSelectorAndActivati...

Page 27: ...Set SetConfiguration SequencerExposureTime Exposure time SequencerExposureTimeMAX To indicate max exposure time that can be set SequencerGain Gain SequencerXSize X size which is set at ROI shall be s...

Page 28: ...p Left Top Right Bottom Left Bottm Right Pix0 Pix1 Pix2 Pix3 Pix4 The information of Index no Loop count in Index and Loop no shall be output for each pixel as below 2bit at LSB side shall always be 0...

Page 29: ...ion False DefectivePixelCorrection True BalanceWhiteControl BalanceWhiteOnePushGainRed 1 0 BalanceWhiteOnePushGainBlue 1 0 DigitalIOControl LineSource OFF SequencerControl SequencerActivation Off Sequ...

Page 30: ...VCC 5CXP3R Rev 905 0052 00 2016 CIS Corporation All rights reserved 29 11 Dimensions 11 1 Optical Axis Accuracy A e g i s E l e c t r o n i c G r o u p I n c...

Page 31: ...VCC 5CXP3R Rev 905 0052 00 2016 CIS Corporation All rights reserved 30 11 2 Camera Dimension A e g i s E l e c t r o n i c G r o u p I n c...

Page 32: ...ure to observe the information contained in the instructions in this Product Specification and Operational Manual In case damages or losses are caused by repair or modification conducted by the custom...

Reviews: