VCC-5CXP3R
Rev. 905-0052-00
©2016 CIS Corporation. All rights reserved.
22
9.3
Trigger Mode
There are 2 types of control in sequence performance.
1. Edge control
2. Pulse width control
・
Please choose from FrameStartRisingEdge/ FrameStartFallingEdge/ FrameStartLevelHigh/ FrameStartLevelLow
to set TriggerSelectorAndActivation in accordance with the way of control. (Edge control or Pulse width control)
(1) Edge Control
TRIG IN
Video Out
Effective Line
Exposure
Effective Line
①
FVAL Out
Sequence Control Start
Sequence Control Finish
Effective Line
Effective Line
②
Effective Line
Effective Line
When TriggerSelectorAndActivation is set to FrameStartRisingEdge orFrameStartFallingEdge, sequence will start
when the trigger is ON.
・
The exposure time (
①
,
②
) for each frame shall be controlled by sequence parameter set which is set beforehand.
・
Sequence performance will end after the sequence loop count of image output, and the performance will stop.
Shutter
Gain
Param #0
Shutter
Gain
Param #1
Shutter
Gain
Param #2
Shutter
Gain
Param #3
Shutter
Gain
Param #4
Shutter
Gain
Param #15
Applying param
Index0
Applying param
Index1
Applying param
Index2
Applying param
Index3
Applying param
Index #4
Applying param
Index #5
Param#0
Param#1
Param#0
Param#1
Param#4
Param#15
200
32
100
32
60
3
1023
1
IndexLoopCount
各Indexを繰り返す回数
SequencerLoopCount
0: 無限loop, 1~: 有限loop数
ActiveIndexNumber
実行するIndexの範囲
ParameterIndexNumber
各Indexとパラメータセットの紐付け
SequencerParameterSetSelector
The repeat count for each Index
0: Infinite loop, 1
~
: finite loop coun
t
The range of Index to be executed
Bind each Index and parameter set