VCC-2CXP6R
Rev.905-0187-02
©2019 CIS Corporation. All rights reserved.
9
5.
Camera Function
5.1.
Settings
Conform to CoaXPress.
5.2.
How to Save and Initialize the Settings
UserSets
UserSetSelector
Default
UserSet0
UserSetLoad
Execute
UserSetSave
Execute
□
If you wish to save the setting values, execute “UserSetSave” by selecting UserSet0 (User save area) of
UserSetSelector. Doing so, the setting values shall be saved in the camera non-volatile memory.
※The value cannot be saved to Default (Factory settings).
※The value of UserSetSelector cannot be saved by UserSetSave. Please set the value before executing
UserSetLoad / UserSetSave.
□
Default (Factory settings) selected by UserSetSelector or UserSet0 (User save area) can be loaded by
UserSetLoad.
※ Please do not execute UserSetLoad when grabbing (acquiring image).
□
Defective pixel correction value and UserID are to be saved when UserSetLoad of Default is executed.
□
Even executing UserSetLoad, ConnectionConfig, PixelFormat, and Imagae Quality Mode shall maintain the
settings of when executing.
Please set the values by command.
UserSetSelector
UserSetLoad >Excute
UserSetSave >Excute
Default
UserSet0
UserSetLoad >Excute
= Initialize(Factory setting)
= Initialize(User setting)
= User setting Save
5.3.
Link Speed and Link Count
Transfer Control
ConnectionConfig
CXP3_X1
CXP6_X1
CXP-3: Link speed=3.125Gbps, Link count=1
CXP-6: Link speed=6.250Gbps, Link count=1
※ Please do not change ConnectionConfig while grabbing (acquiring image).