Summary of Contents for QA Phantom 008Z

Page 1: ...IMAGE ACQUISITION TREATMENT PLANNING DOSE DELIVERY USER GUIDE MRgRT Motion Management QA Phantom Model 008Z 900 Asbury Ave Norfolk Virginia 23513 USA Tel 757 855 2765 WWW CIRSINC COM ...

Page 2: ... Assembly Procedure 6 Model 008Z Cables and Connections 7 Setup notes for Dynamic Phantoms with controller connecting to a PC using an Ethernet connection 8 CIRS Motion Control Software 10 Model 008Z Specifications 11 Warranty 12 Notes 13 Table of Contents ...

Page 3: ...ckground gel which fills the void between the organs Besides imaging all organs except for the lungs offer ion chamber dosimetry cavities which allow for completing an entire QA process from imaging to planning to verification of dose delivered Our phantom is designed as a single unit with a piezo actuator fixed perma nently to a base plate on which the MRI body snaps This allows for quick setup r...

Page 4: ...ed check with a qualified electrician Do not remove ground prong Do not install or use this product near water or when you are wet Operate the product securely on a stable surface Set up the product in a protected location where no one can step on or trip over the power cord and the power cord can not be damaged It is recommended that the customer install an AC surge arrestor in the AC outlet to w...

Page 5: ...ntains potential dam aged goods The sensor displays a red arrow when applied before shipping If the container receives a shock exceeding 25 G force the sensor display arrows will change to blue If the sensor has been activated and is blue a claim may need to be filed with the carrier If activated take extra care in inspecting the compo nents as they are unpacked assembled and tested Note If there ...

Page 6: ...image above 2 Place rod into phantom body and screw the rod and actuator together 3 Insert ion chamber into each cavity hole Moving target 4 Insert ion chamber into each cavity hole Liver 5 Insert ion chamber into each cavity hole Kidney 6 Insert ion chamber into each cavity hole Spine ...

Page 7: ...ller and actuator powered and ready for use 4 Plug beam latency BNC cable into the back of the controller To perform beam latency connect the other end of the BNC cable to the Beam on Beam off output signal of the MRI LINAC Cables and Connections WARNING FOLLOW THE CABLE CONNECTION STEPS AS THEY ARE PRESENTED IN THIS USER GUIDE CONNECTING THE CABLES WITH THE CONTROLLER POWER ON CAN SERIOUSLY DAMAG...

Page 8: ...d above 1 To install the necessary driver unzip the USB to Network Adapter folder found on the provided USB drive or download the zipped folder from the CIRS website Archive to a known location and select autorun 3 Follow the on screen steps and acknowledge all the mes sages related to driver s installation Once the driver installa tion is finished plug the USB to Network Adapter into your PC s US...

Page 9: ... 0 249 8 Once the IP address is entered click OK Connect the PC to the Controller using the provided Ethernet cable by inserting one end of the cable in the controller s Ethernet port and the other one in the USB to Network Adapter Power on the controller To check that the PC to controller connection was successful ensure the icon of the ASIX AX88179 USB 3 0 to Gigabit Ethernet Adapter in the Cont...

Page 10: ...mputer computer optional The software automatically creates a log file where data about wave form parameters are saved The log file is usually located under the current user in the Application Data folder A Windows OS search function can be used to find the log file Searching hidden files and folders should be enabled The log file provides a record of the motion history of the device and can be us...

Page 11: ... 50 60Hz 1 Actuator base plate assembly 1 CIRS Motion Control Software 1 Communication cables kit Ethernet cable adapter 1 User s guide 2 Carry Case OVERALL DIMENSIONS 67 cm x 32 cm x 20 cm OVERALL WEIGHT 12 kg 26 5 lbs AMPLITUDE IS 25 mm AMPLITUDE AP LR 3 5 mm MOTION ACCURACY 0 2 mm linear motion MOTION ACCURACY 0 25o rotation motion CYCLE TIME 1 adjusted based on amplitude WAVEFORMS sin t 1 2cos...

Page 12: ...not satisfied with your purchase for any reason please contact your local distributor prior to returning the product Visit https www cirsinc com distributors to find your local distributor If you purchased your product direct through CIRS call Customer Service at 800 617 1177 email rma cirsinc com or fax an RMA request form to 757 857 0523 CIRS staff will attempt to remedy the issue via phone or e...

Page 13: ...13 NOTES ...

Page 14: ...14 NOTES ...

Page 15: ...15 NOTES ...

Page 16: ... notice Publication 008Z UG 110320 Computerized Imaging Reference Systems Inc has been certified by UL DQS Inc to ISO 13485 2016 Certificate Registration No 10000905 MP2016 COMPUTERIZED IMAGING REFERENCE SYSTEMS INC 900 Asbury Ave Norfolk Virginia 23513 USA Toll Free 800 617 1177 Tel 757 855 2765 Fax 757 857 0523 Email admin cirsinc com www cirsinc com Technical Assistance 1 800 617 1177 ...