3-12
P/N 11934-003
Section 3
Cirrus Design
Emergency Procedures
SR20
Engine Airstart
The following procedures address the most common causes for
engine loss. Switching tanks and turning the fuel pump on will
enhance starting if fuel contamination was the cause of the failure.
Leaning the mixture and then slowly enriching mixture may correct
faulty mixture control.
• Note •
Engine airstarts may be performed during 1g flight anywhere
within the normal operating envelope of the airplane.
1. Bat Master Switches ................................................................. ON
2. Power Lever .................................................................... ½” OPEN
3. Mixture ................................................................ RICH, AS REQ’D
4. Fuel Selector ........................................................ SWITCH TANKS
5. Ignition Switch ....................................................................... BOTH
6. Fuel Pump.......................................................................... BOOST
7. Alternate Induction Air............................................................... ON
8. Alt Master Switches .................................................................OFF
9. Starter (Propeller not Windmilling) ...................................ENGAGE
10. Power Lever .......................................................slowly INCREASE
11. Alt Master Switches .................................................................. ON
12. If engine will not start, perform
Forced Landing
checklist.
Revision A5
Summary of Contents for SR20
Page 10: ...1 2 P N 11934 003 Section 1 Cirrus Design General SR20 Intentionally Left Blank Revision A3 ...
Page 22: ...2 2 P N 11934 003 Section 2 Cirrus Design Limitations SR20 Placards 2 21 Revision A6 ...
Page 308: ...9 2 P N 11934 003 Section 9 Cirrus Design Supplements SR20 Intentionally Left Blank Reissue A ...