Section 11: Rework and Guided Assembly / Removing shorts between nets
1000R+ User’s Guide / page 56
analyzer may prompt
Intermittents
as you rework the connection. To clear this
prompt, press the
Memory
button on the back of the analyzer.
Removing shorts
between nets
If the analyzer detects short circuits in the cable or harness you are testing, it will tell
you where to make cuts to correct the shorts. This will happen if two nets should
become shorted. To correct a detected short, do these things:
1.
The analyzer will prompt
Cut JX-XX From JX-XX
, where X indicates the
adapter positions and pin number.
2.
Locate the short between the nets, and remove it.
Please see next page...
G O O D C A B L E
B R E A K J X -X X
C a b le h a s b e e n c o rre cte d
Yo u ’ve cre a te d a n o th e r s h o rt.
G o b a ck a n d try a g a in
C U T JX -X X
F R O M JX -X X
Summary of Contents for Signature 1000R+
Page 1: ...Signature 1000R Cable Analyzer User s Guide Version 4 0 Major Revision 23 September 1999...
Page 3: ......
Page 5: ...1000R User s Guide page 6...
Page 7: ...Introduction to the Cirris 1000R What your order should contain 1000R User s Guide page 8...
Page 15: ...Section 1 Work With the Hardware Changing the company name 1000R User s Guide page 16...
Page 20: ...Section 3 What the Option Settings Mean Auto Print 1000R User s Guide page 21...
Page 21: ...Section 3 What the Option Settings Mean Auto Print 1000R User s Guide page 22...
Page 51: ...Section 10 Select a Test Procedure Testing harnesses and backplanes 1000R User s Guide page 52...
Page 71: ...Section 13 Specifications Warranty 1000R User s Guide page 72...
Page 73: ...Section 14 Statement of Warranty 1000R User s Guide page 74...
Page 77: ...Section 15 Glossary short 1000R User s Guide page 78...
Page 79: ...Section 16 Blank Forms to Photocopy 1000R User s Guide page 80...
Page 81: ......
Page 83: ......
Page 88: ......