1000R+ User’s Guide / page 41
Types of Tests
Using the Cirris 1000R+, you can perform two different kinds of tests. These are:
1.
Simple tests.
2.
Complex tests.
Simple Tests
Simple tests are used for testing cables made up of only wires and connectors. These
cables have no resistors, capacitors, diodes, or any active circuitry. Set the Connection
Resistance to a low number (typically less than 10
Ω
). Depending on the capacitance
of the cable, set the Insulation Resistance to a higher setting.
This table will give you general guidelines for setting up simple tests. You can adjust
the settings to meet your specific needs.
General Guidelines for Simple Tests
Type of Test
Connection
Resistance
Insulation
Resistance
Comments
Calculating
Resistances Only
CALC
NA
Use CALC to help you determine where
to set your Conn. Resis. threshold. In
CALC, the 1000R+ displays the actual
resistance measured between points.
NOTE: you should CALC several cables
to get a good sampling, then set your
own threshold. DO NOT use CALC for
testing!
Automatic Test
AUTO
NA
(Automatically
set to 5 M
Ω
)
AUTO selects a Conn. Resis. threshold
for you. It takes the highest resistance
measured between any two points and
adds 20%. Warning: If you get a Sam-
ple Cable with high resistance when
learning in AUTO, you may be testing at
a much higher threshold than you want.
Use CALC to determine a better Conn.
Resis. threshold, then set it yourself.
Fast Test
1 K
Ω
1 K
Ω
The fastest possible test. This setting
effectively emulates a continuity tester.
Typical Test
0.5
Ω
100K
Ω
Use these settings when low connection
resistance is important and insulatiion
resistance is not critical. Low connec-
tion resistance may require more care-
ful adapter maintenance.
Stringent Test
0.5
Ω
5M
Ω
Use these settings for stringent and
slow testing, when you require low con-
nection resistance and extremely good
insulation resistance. This test requires
careful adapter maintenance
Section 10:
Select a Test
Procedure
Summary of Contents for Signature 1000R+
Page 1: ...Signature 1000R Cable Analyzer User s Guide Version 4 0 Major Revision 23 September 1999...
Page 3: ......
Page 5: ...1000R User s Guide page 6...
Page 7: ...Introduction to the Cirris 1000R What your order should contain 1000R User s Guide page 8...
Page 15: ...Section 1 Work With the Hardware Changing the company name 1000R User s Guide page 16...
Page 20: ...Section 3 What the Option Settings Mean Auto Print 1000R User s Guide page 21...
Page 21: ...Section 3 What the Option Settings Mean Auto Print 1000R User s Guide page 22...
Page 51: ...Section 10 Select a Test Procedure Testing harnesses and backplanes 1000R User s Guide page 52...
Page 71: ...Section 13 Specifications Warranty 1000R User s Guide page 72...
Page 73: ...Section 14 Statement of Warranty 1000R User s Guide page 74...
Page 77: ...Section 15 Glossary short 1000R User s Guide page 78...
Page 79: ...Section 16 Blank Forms to Photocopy 1000R User s Guide page 80...