32
SMART PLUGGING
[ENG]
SAVING IS
SIMPLE WITH
WI-BEEE
Page 1: ...32 SMART PLUGGING ENG SAVING IS SIMPLE WITH WI BEEE ...
Page 2: ...2 Introduction 3 Overview 4 Instructions 6 Technical Specifications 10 Safety Precautions 10 External Connections 11 LEDs 12 Wi beee Set up on Breaker Installation 12 Technical Features 13 ...
Page 3: ... powered up it will start converting the measured parameters into info by sending them via wireless These units can be installed at any point of the installa tion and will help detect any hot spot where the current is not being used efficiently and therefore very much help in drastically reducing energy consumption by re motely activating the alarms when the desired limits are passed All these ene...
Page 4: ...4 Electrical Panel Wi beee Overview ...
Page 5: ...5 Laptop PC Smartphone Tablet ...
Page 6: ...ins tallation your device could be damaged if a bad installation is made 3 Put the magnetics connectors in direction to circuit breaker Before using Wi beee ensure that the con ditions are the appropriate for working and that the protection equipment is the adequate 4 Press the device to ensure the engage 5 Put the conductor of each line close to the Wi beee body ...
Page 7: ...Attention Refer to manual Double Isolation SYMBOLS 6 Verify that the led red is on and blink 7 After a few seconds the led blue turns blinking Do not apply around or remove from hazar dous live conductors ...
Page 8: ...t to Wibeee 2 You can get access to the net configuration and instantane ous measures through your browser http 192 168 1 150 User user Password user 2 1 Scan the QR code to down load the app or get it from http wibeee circutor com 2 Open the app Wibeee CIRCUTOR 3 Follow the steps indica ted by the app ...
Page 9: ...9 1 Now you have access to analysis your data trough Wibeee CIRCUTOR 3 2 Or you can get access to analysis your data through the website http wibeee circutor com ...
Page 10: ...he Wi beee for the first time read the following carefully 1 Circutor does no take responsibility for damage or physical injury that may be caused as a result of improper installa tion or use of equipment 2 Use of the Wi beee on uninsulated conductors is limited to 265 V to power frequency 3 Do not expose the to aggressive or explosive environment Technical Specifications ...
Page 11: ...equirements system administrator You must open the following ports Port 8080 for Http Get Post Port 53 for DNS Port 80 for Internet 4 Do not use the Wi beee if there any reason to think that its no operating properly or that it is faulty 5 For measuring in uninsulated conductor use the appro priate and necessary personal protection equipment ...
Page 12: ...N L N L1 L2 L3 3 LEDs Red LED Blinking Powered device Blue LED it indicates the connection status Slow blinking 1s No link to a Wi Fi network Fast blinking 1s Link to a Wi Fi network Fixed on Sending data over the network Single phase Three phase ...
Page 13: ...ements range Nominal range current 500mA 65 A Accuracy 2 Variation in range of use 5 5 Nominal range voltage 85 265 V Accuracy 2 Variation in range of use 5 5 Power Accuracy 4 Variation in range of use 5 5 Communications Transceptor Wi Fi IEEE 802 11 Frequency Range 2 405 2 48 GHz Encryption AES128 Certification FCC EE UU IC CANADÁ ETSI EUROPA 5 4 Communications 1 The metrological specifications g...
Page 14: ... current 1 Conductor position 2 3 Adjust Full Scale 0 2 0 4 Distance between wire and sensor 2 5 0 1mm 5 6 Standards Standards UNE EN 61010 2 030 2011 UNE EN 61326 1 2006 EN 301 489 17 V2 2 1 Operating temperature 10 C 45 C Storage temperature 40 C 85 C Protection degree IP20 Surround Self extinguishable UNE 21031 90 C Maximum altitude 2000 m 5 7 Mechanical and Environment features ...
Page 15: ...15 5 8 Dimensions 80 50 5 28 20 22 49 50 5 28 20 22 Single phase Three phase ...
Page 16: ...16 SMART PLUGGING ...
Page 17: ... CIRCUTOR SAT 902 449 459 SPAIN 34 937 452 919 Out od Spain Vial Sant Jordi s n 08232 Viladecavalls Barcelona Spain Tel 34 93 745 29 00 Fax 34 93 745 29 14 sat circutor es www circutor com M072B01 20 15B ...