Raption 150C
Instruction Manual
88
Value
Description
Include Power Active
Import in MeterValues
ENABLED:
Send power (Power.Active.Import) and energy (En-
ergy.Active.Import.Register) consumed by the vehicle within
meter values requests.
DISABLED:
Only enrgy consumed is sent within meter values
request.
Energy for Start/Stop
transaction
PARTIAL:
Consumed value of energy by the vehicle sent be-
tween start and stop.
TOTAL:
Count of the total accumulated energy meter sent be-
tween start and stop.
User confirmation on HMI
required on Remote Start
Transaction
ENABLED:
Charge point sends an authorization request be-
fore starting a new remote charge transaction request.
DISABLED:
Charge point starts a new remote charge transac-
tion without authorization request.
Authorize always in
offline mode
ENABLED:
If user is not present locally in the local white-list
and charge point cannot ask to the backend, the user is al-
lowed to start a new charge transaction.
DISABLED:
If user is not present locally in the local white-list
and charge point cannot ask to the backend, the user is not
allowed to start a new charge transaction.
Authorization check order
LOCAL:
ID authorization has first place on the local white-list.
If the user does not exist locally, then in second place backend
is asked to obtain the authorization.
CS:
ID authorization is always asked to the backend.
Note:
This setting only applies when Charge Point is online;
otherwise the authorization is only locally.
Summary of Contents for RAPTION 150C CCS CHA
Page 1: ...Raption 150C Series INSTRUCTION MANUAL M358B01 03 22A...
Page 2: ...Raption 150C Instruction Manual 2...
Page 32: ...Raption 150C Instruction Manual 32 3 CONNECTOR DISABLED 4 CONNECTOR IN USE...
Page 35: ...Raption 150C Instruction Manual 35...
Page 59: ...Raption 150C Instruction Manual 59...
Page 93: ...Raption 150C Instruction Manual 93...
Page 107: ...Raption 150C Instruction Manual 107 Monitoring...
Page 115: ...Raption 150C Instruction Manual 115...