ANNEX A.- CONFIGURATION MENU

 A�1�- DCB-72 mAdc

Display value

Software version

Units of the Display 

value

Measurement 

range

Units of the Measurement 

range

Password off access

Brightness of the 

display

Light alarm

  uEr  

 

3012

  

oFF

 

0-20

  

oFF

 

120.0

  

on

 

4-20

 

0001

 

20.20

CodE

 

0000

 

5.000

 

rEAd

 

inPt

  

SEt

>3s

 

ProG

in  i

Unt. i

in 2

Unt.2

 

000.0

CodE  

  Alr

   

L1

LiGH  

   

L5

  uEr  

Figure 17:Configuration menu DCB-72 mAdc

34

DCB-72 mAdc, DCB-72 Adc

Instruction Manual

Summary of Contents for DCB-72 Adc

Page 1: ...INSTRUCTION MANUAL M208B01 03 21A DC Ammeter DCB 72 mAdc DCB 72 Adc...

Page 2: ...2 DCB 72 mAdc DCB 72 Adc Instruction Manual...

Page 3: ...ing should be taken into consideration Incorrect handling or installation of the unit may result in injury to personnel as well as damage to the unit In particular handling with voltages applied may r...

Page 4: ...MEASUREMENT RANGE 18 5 1 5 SAVE CONFIGURATION 19 5 2 RELAY OUTPUT 1 20 5 2 1 RELAY MODE 21 5 2 2 RELAY PULSE DURATION 21 5 2 3 ALARM PARAMETER 22 5 2 4 CONNECTION DELAY 22 5 2 5 ALARM VALUE 23 5 2 6 H...

Page 5: ...nges in the following sections 3 3 4 3 5 2 5 5 2 6 Note Devices images are for illustrative purposes only and may differ from the actual device SYMBOLS Table 2 Symbols Symbol Description In compliance...

Page 6: ...n immediately contact the transport com pany and or CIRCUTOR s after sales service 2 PRODUCT DESCRIPTION The DCB 72 Adc range is designed to measure and display the DC current CIRCUTOR has 2 models fo...

Page 7: ...ower Supply Relays 80 270 V 80 270 V 18 36 V M22260 M22262 M222600030000 M222620030000 DCB 72 Adc Table 4 DCB 72 Adc list of models DCB 72 mAdc Model Power Supply Relays 80 270 V 80 270 V 18 36 V M222...

Page 8: ...condition in order to avoid accidents personal injury and damage to installations The device s functionality is limited to the category of measuring voltage or specific current values The manufacturer...

Page 9: ...l it take the following steps 1 Make a cut in the panel according to the dimensions in Figure 1 67 67 Figure 1 Cut in the panel 2 Remove the device s fixing clips Figure 2 Clip de fijaci n Fixing clip...

Page 10: ...O Version 2 0 Table 6 List of terminals of the DCB 72 Adc Version 2 0 Device terminals 1 L Power supply 28 1 Alarm output 1 relay NO 2 N Power supply 31 1 Alarm output 1 and 2 relay Common 4 Current m...

Page 11: ...ement DCB 72 Adc Make sure that the positive and negative current terminals are as shown in the connection diagram Note The current measurement cable can be directly connected to the terminals of the...

Page 12: ...y the negative values 4 2 KEYBOARD FUNCTIONS The DCB 72 Adc features 4 keys to display and configure the device Figure 5 Table 7 Keyboard functions Key Keystroke Previous screen In the configuration m...

Page 13: ...or 2 display screens Table 8 Use the and keys to browse the screens Table 8 Display menu Display menu 5 000 Current Note only available for models with relay outputs do 12 Status of the relay outputs...

Page 14: ...Relay output 1 2 Relay output 2 2 Configuration of the display Software version Figure 6 Configuration menu of the DCB 72 Adc 2 Only available for models with relay outputs From any screen of the con...

Page 15: ...efore accessing the configuration menu it is necessary to enter the access password CodE 0000 Figure 8 Access password Use the key to modify the value of the flashing digit When the desired value is s...

Page 16: ...u from which the primary current and secondary current are configured inPt Figure 9 Input configuration menu main screen Press the key to open the configuration menu inPt in i Unt i in 2 Unt 2 000 0 o...

Page 17: ...t Use the to modify the decimal point Minimum configuration value 0 Maximum configuration value 9999 To validate the data press the key Use the and keys to browse the configuration screens of the menu...

Page 18: ...A 4 20 for the current scale of 4 20 mA 20 20 for the current scale of 20 mA Options for the DCB 72 Adc model 1 000 for the current scale of 0 1A 5 000 for the current scale of 0 5A To validate the da...

Page 19: ...is opened Figure 9 Press the key again to show the validation screen SAuE no Use the key to browse the different options no exit the configuration without saving the changed values YES save the change...

Page 20: ...of the configuration menu of relay output 1 do 1 Figure 11 Configuration menu of relay output 1 main screen Press the key to open the setup menu do 1 nodE tinE itEn dELy HyS uALE 000 0 0000 0010 oFF 0...

Page 21: ...de activated 2 The relay is activated when the alarm is triggered and is deactivated after a programmed period of time even though the alarm condition has not been cancelled This screen is used to con...

Page 22: ...rowse the configuration screens of the menu 5 2 4 CONNECTION DELAY This screen is used to configure the alarm connection delay dELy 0010 Use the key to modify the value of the flashing digit When the...

Page 23: ...the and keys to browse the configuration screens of the menu 5 2 6 HYSTERESIS This screen is used to configure the hysteresis value i e the difference between the alarm connection and disconnection v...

Page 24: ...iguration without saving the changed values YES save the changed configuration values Press the key to validate the data and exit the configuration menu 5 3 RELAY OUTPUT 2 Note Only available for mode...

Page 25: ...Figure 15 Configuration menu of the display 5 4 1 PASSWORD OFF ACCESS This screen is used to configure the value of the password used to access the configuration menu in the programming mode CodE 000...

Page 26: ...LARM If the current value measured by the device is higher than a of the nominal value the device can make the digits on the display start flashing in the form of a light alarm Alr 120 0 Use the key t...

Page 27: ...show the validation screen SAuE no Use the key to browse the different options no exit the configuration without saving the changed values YES save the changed configuration values Press the key to va...

Page 28: ...rement circuit Nominal current In DCB 72 mAdc 20 mA 0 20 mA 4 20 mA DCB 72 Adc 1 A 5 A Sobrecorriente 1 2 In continuous 10 In Instantaneous 5s Consumption 0 2 VA Impedance DCB 72 mAdc 10 DCB 72 Adc 20...

Page 29: ...measurement te chniques Electrical fast transient burst immunity test IEC 61000 4 4 Electromagnetic compatibility EMC Part 4 5 Testing and measurement te chniques Surge immunity test IEC 61000 4 5 El...

Page 30: ...er installation or improper usage of the unit Consequently this guarantee does not apply to failures occurring in the following cases Overvoltages and or electrical disturbances in the supply Water if...

Page 31: ...9 CE CERTIFICATE 31 Instruction Manual DCB 72 mAdc DCB 72 Adc...

Page 32: ...32 DCB 72 mAdc DCB 72 Adc Instruction Manual...

Page 33: ...33 Instruction Manual DCB 72 mAdc DCB 72 Adc...

Page 34: ...nge Units of the Measurement range Password off access Brightness of the display Light alarm uEr 3012 oFF 0 20 oFF 120 0 on 4 20 0001 20 20 CodE 0000 5 000 rEAd inPt SEt 3s ProG in i Unt i in 2 Unt 2...

Page 35: ...n Password off access Brightness of the display Light alarm Alarm value Hysteresis uEr 3012 0 20 4 20 oFF oFF i H on oFF 120 0 0001 rEn ALr 1 L 20 20 CodE 0000 5 000 rEAd inPt do 1 3s ProG in i Unt i...

Page 36: ...the Measurement range Password off access Brightness of the display Light alarm uEr 3012 5 000 1 000 oFF oFF 120 0 on 0001 CodE 0000 5 000 rEAd inPt SEt 3s ProG in i Unt i in 2 Unt 2 000 0 CodE Alr L...

Page 37: ...y pulse duration Alarm parameter Software version Password off access Brightness of the display Light alarm Alarm value Hysteresis uEr 3012 5 000 1 000 oFF oFF i H on oFF 120 0 0001 rEn ALr 1 L CodE 0...

Page 38: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor com central circutor com...