A bar chart with the indications of the instantaneous value, maximum and minimum
values and alarms, see
Table 27:Instantaneous parameters (display 4 parameters)�
Icon
Display 4 parameters
Instantaneous parameters
Icon
Display 4 parameters
Instantaneous parameters
Phase-Neutral Voltage L1
Phase-Neutral Voltage L2
Phase-Neutral Voltage L3
Phase-Neutral Voltage III
Capacitive reactive power L1
(16)
Capacitive reactive power L2
(16)
Capacitive reactive power L3
(16)
Capacitive reactive power III
(16)
Neutral voltage
Total reactive power L1
(15) (16)
Total reactive power L2
(15) (16)
Total reactive power L3
(15) (16)
Total reactive power III
(15) (16)
Phase-Phase Voltage L1-L2
Phase-Phase Voltage L2-L3
Phase-Phase Voltage L3-L1
Phase-Phase Voltage III
Apparent power L1
(16)
Apparent power L2
(16)
Apparent power L3
(16)
Apparent power III
(16)
Current L1
Current L2
Current L3
Current III
Power Factor L1
(15) (16)
Power Factor L2
(15) (16)
Power Factor L3
(15) (16)
Power Factor III
(15) (16)
Neutral current
(14)
Cosine phi L1
(15) (16)
Cosine phi L2
(15) (16)
Cosine phi L3
(15) (16)
Cosine phi III
(15) (16)
Frequency
Voltage THD L1
(16)
Voltage THD L2
(16)
Voltage THD L3
(16)
Voltage THD LN
(16)
Active power L1
(16)
Active power L2
(16)
Active power L3
(16)
Active power III
(16)
Current THD L1
(16)
Current THD L2
(16)
Current THD L3
(16)
Current THD LN
(16)
Inductive reactive power L1
(16)
Inductive reactive power L2
(16)
Inductive reactive power L3
(16)
Inductive reactive power III
(16)
(14)
In the
CVM-A1x00-FLEX
version, the neutral current is a calculated parameter, except in Single-Phase con-
nection mode, where it is not supported.
(15)
The following icons appear for all these parameters on the screen:
Indicating that the parameter refers to inductive or
capacitive energy.
(16)
The following icons appear for all these parameters on the screen:
Indicating that the parameter refers to consumed or
generated energy.
If the 2 icons light up at the same time, it means the installation is not properly
connected.
If there is an alarm associated with the variable being displayed, the following will be shown:
The module with which the alarm is associated.
The associated output in the module.
The alarm status:
not activated,
pre-alarm activated,
alarm activated.
107
Instruction Manual
CVM-A1000 - CVM-A1500