background image

LIMITED WARRANTY

Circuit-Test Electronics warrants to the original purchaser that

this product be free of defect in material or workmanship for a

period of 2 years from the date of purchase. If this product

requires warranty service, return the unit (freight prepaid),

together with your dated proof of purchase and explanation of

the defect to:

In Canada:

Circuit-Test Electronics

(Division of R.P. Electronic Components Ltd.)

2060 Rosser Avenue

Burnaby, BC, V5C 5Y1

Any product which has been subjected to misuse or accidental

damage is excluded from the warranty. Except as stated above,

Circuit-Test Electronics makes no promises or warranties either

expressed or implied including warranties of merchantability or

the fitness for any particular purpose. This warranty gives you

specific legal rights and you may have other rights which vary

under the laws of the various countries, states or provinces in

which Circuit-Test Electronics operates.

ACCESSORIES

Test Leads (set)   TL-120

Hard Carrying Case (optional)   

CS-280

OWNER’S MANUAL

DIGITAL MULTIMETER

DCL-280

CIRCUIT -TEST

ELECTRONICS

INTRODUCTION

Your Circuit-Test DCL-280 Digital Clamp-on
Meter incorporates the latest technology to pro-
vide you with a feature packed instrument. With
it you can measure a wide range of voltages,
current, resistance and frequency in the lab,
shop, car and home. This meter has been
designed for the Electrician, Technologist,
Hobbyist and Educational Institutions.

FEATURES

Frequency - display frequency to 20KHz

AC Current - measure to 600A AC

Continuity Buzzer - easily check for continuity.

Diode Check - test diodes and other semicon-
ductors for open & short circuits.

Auto Power Shut-Off - meter automatically
shuts off 30 minutes after last operation

Overload Protection - protects the meter from
overvoltage and incorrect range selection

PRINTED IN TAIWAN

!

 WARNING

1.

Always start with the power off. Set the
range switch correctly before making any
measurements.

2.

Do not operate the unit unless the case is
completely closed.

3.

Disconnect test leads from equipment
before removing the battery or fuse.

4.

Never connect unit to AC or DC powered
circuits when the range switch is set to
resistance, diode check or continuity ranges.

5.

To safeguard against electrical shock or
damage to instrument, never connect to
more than 600V DC or 600V AC between
input jacks and ground when measuring
low energy circuits or 250VAC / 250VDC
when measuring high energy circuits.

6.

When using the test probes always keep
your fingers behind the finger guards on the
probes. Never touch the exposed probe tip.

7.

Always inspect the instrument, test leads
and other accessories for damage prior to
use.

8.

Disconnect the live / positive test lead prior
before disconnecting the common / negative
test lead.

9.

Read this instruction manual carefully and
completely before using.

!

 SAFETY PRECAUTIONS

This meter is not recommended for high voltage
industrial use; for example, do not use for meas-
urements on 440VAC or 600VAC industrial
power mains. The unit is intended for use with
low energy circuits to 600VDC / 600VAC or high
energy circuits to 250VAC / 250VDC only.

High voltage AC and DC circuits are dangerous.
Use caution when working above 60VDC or
30VAC rms as these voltages pose a shock
hazard. Always consider circuits to be ener-
gized. Never assume any equipment is
de-energized. Lack of caution or poor safety
practices can be very dangerous and/or lethal.

SPECIAL FUNCTION

Max Data Hold - When PEAK-H is pressed, the
last reading is held on the display.