OG_MU-4-434_v10e Circuit Design, Inc.
51
OPERATION GUIDE
5.4.3.3 @RA RSSI absolute value measurement
Measures the absolute value for Received Signal Strength Intensity (RSSI) of the channel set. The measured value
is a hexadecimal value that indicates the RSSI absolute value.
The code of the RSSI value acquired is minus.
Format 1: ‘@’ + ‘RA’ + ‘CRLF’
Details
Format:
‘@RA
C
R
L
F
’
Range of the hexadecimal value that indicates the RSSI absolute value: 00h to FFh
Example: Measure the RSSI absolute value of the current channel
Monitor command: @RA
C
R
L
F
Monitor response:
When RM = CD *
RA
C
R
L
F
*63h = 99
(When RM = TX *
RA
=
63 -
99dBm
C
R
L
F
)
5.4.3.4 @RC All channel RSSI absolute level measurement
Measures the RSSI (Received Signal Strength Intensity) over all channels. It is possible to check the floor noise
level of the field, third party field level, and field level of the system itself. The measured value is output as a 2-digit
hexadecimal number in ASCII characters that expresses the absolute value for RSSI. The code of the RSSI value
acquired is minus.
Format 1: ‘@’ + ‘RC’ + ‘CRLF’
Example: Measure the RSSI absolute value over all channels.
Monitor command: @RC
Monitor response: *RC = 7A7C7D....7E7D
C
R
L
F
A response is returned for 64 channels of RSSI data (128-byte ASCII characters)
The code is minus. 7A = -122dBm