OG_MU-4-434_v10e Circuit Design, Inc.
31
OPERATION GUIDE
5.2.3 Control commands and control responses
Command type
Command name
Command format
Control response format
(Command response)
Page
reference
Radio link
related setting
and acquisition
commands
User ID setting
@UI XXXX,XXXX
*UI = XXXX
48
Group ID setting
@GI XX
*GI = XX
44
Equipment ID setting
@EI XX
*EI = XX
44
Destination ID setting
@DI XX
*DI = XX
43
Relay route designation
@RT XX,XX,..,XX
*RT = XX,XX,..,XX
46
Channel setting
@CH XX
*CH = XX
42
UART parameter
setting
commands
UART baud rate setting
@BR ww
*BR = ww
42
UART parity setting
@PB ww
*PB = ww
44
UART stop bit setting
@SB ww
*SB = ww
46
Operation setting
and information
acquisition
commands
Operation mode setting
@MD ww
*MD = ww
44
Command mode input waiting time setting
@TC XX
*TC = XX
48
Time without input in the binary mode
setting
@TB XX
*TB = XX
47
Attach route information mode setting
@RI ww
*RI = ww
45
Response display mode setting
@RM ww
*RM = ww
45
Program version acquisition
@VR
*VR = XX ww...ww
48
Serial number acquisition
@SN
*SN = wwwwwwwww
47
Reset
@SR
*SR = 00
47
Initialize
@IZ
*IZ = 00
44
Standby mode setting
@SY XX
No response
47
Mode setting with RF received signal level
information
@SI ww
*SI = ww
46
Receive route information use setting
@RR ww
*RR = ww
45
Antenna power setting
@PW ww
*PW = ww
45
Error correction protocol setting
*1
@EC ww
*EC = ww
43
*1
: The protocol used when the error correction protocol is off is defined as a standard protocol.
5.2.4 Monitor commands and monitor responses
Command name
Command
format
Monitor response format
(Command response)
Response type
Page
reference
RSSI absolute level measurement
@RA
*RA = XX
No response
51
Target station all channel RSSI absolute level measurement
@CA
*CA = 00
Receive
response
49
Target station RSSI absolute level measurement
@CR
*CR = 00
Receive
response
50
All channel RSSI absolute level measurement
@RC
*RC = XX...XX
No response
51
*RSSI: Received Signal Strength Intensity