Installation
44
TT Twin-Screw Pump -
Installation, Operation & Maintenance Manual
When to install
You may need to install auxiliary piping for gear / bearing cooling, mechanical seal flush, or
other special features supplied with the pump. Consult the pump GA or outline drawing for
specific auxiliary piping requirements and connection points.
Checklist
Check
Explanation/comment
Checked
Check that the minimum flow for each
component meets or exceeds the GA /
outline drawing value
–
Check that the supplied pressure does
not exceed the GA / outline drawing
maximum allowable value
–
Final piping checklist
Check
Explanation/comment
Checked
Check that the shaft rotates smoothly.
Rotate the shaft by hand. Make sure there is no
binding or rubbing that can potentially lead to excess
heat generation or sparks.
Re-check the alignment to make sure
that pipe strain has not caused any
misalignment.
If pipe strain exists, then correct the piping
arrangement.