  During start-up, start the motor with a low-speed set point if possible, then gradually increase 

speed to the intended operating speed.  An acceleration rate of 200 rpm / sec or less is 
recommended; 50 rpm / sec is best, allowing ample acceleration time for downstream apparatus 
to fill gradually with fluid, and for pressure to rise slowly. 

 

C.8  Operation and Maintenance 

 Safety 

 

i

 

NOTE

 

 

The manufacturer’s warranty will be void if any part is replaced, or the pump is modified in any 

way, without permission from Imo Pump. 

 

 

DANGER

 

 

Dead-head condition occurs when the there is a blockage upstream and the pump attempts to 
reach the maximum pressure achievable at a given speed, with a given fluid viscosity.   
 
Reaching the dead-head condition may cause the pump to fail, or for piping limits to be 
exposed. 

 

 

WARNING

 

 

Downstream pressure can change rapidly once the pump is started.  If the downstream flow 
passages are blocked or valves are closed, the pump will likely reach dead-head condition 
before valves can be opened or the blockage removed.   

 

i

 

NOTE

 

 

Only 

trained, specialized personnel

 are qualified to perform maintenance, which includes, but 

is not limited to: 

o

  Inspection 

o

  Repair 

o

  Assembly 

o

  Disassembly 

 
Contact Imo Pump for information on training personnel. 

 

Measure the pump temperature after installation, and monitor temperature during operation.  Rapid 
changes in temperature, while process temperatures and ambient temperatures are stable, signals a 
pending failure.  Make use of every provided temperature measurement connection point, i.e. 
thermocouple mounting points, etc.   

 

C.9   Airborne Noise 
 

The Airborne noise levels of the Pumps are lower than the levels generated by the motor used to drive  the 
pumps. Please refer to Motor Manual for Sound Power level data.  

  

C.10  Pumps with Magnetic Coupling 
 

Magnetic couplings use strong permanent-magnets, which generate a strong magnetic field. The installation 
must be carried out only by trained, specialized personnel. All installation instructions must be strictly 
followed. Modifications or changes to the magnetic coupling, or its components, are not allowed. The 
manufacturer does not take responsibility for damage caused by improper use. 

 

 

Summary of Contents for 2BIC Series

Page 1: ...Safety and Operation WARNING These instructions should be read thoroughly by all personnel involved with pump operation prior to pump installation operation or maintenance Manual No SRM00100 Rev 02 1...

Page 2: ...Transportation of Pumps 10 D 2 Storage Spare Parts 10 E Installation Start up 11 E 1 General 11 E 2 Tools 11 E 3 Installation Preheating Start up 11 E 3 1 Lubrication Preparation 11 E 3 2 Preheating C...

Page 3: ...s Read observe and follow this manual and the other applicable documents especially all safety instructions and warnings A 2 Other Applicable Documents Document Purpose Product Service Manual Detailed...

Page 4: ...ntially Hazardous Situation Minor Bodily Harm Material Damage Symbol Meaning Safety Warning Take note of all information highlighted by a Safety Warning Sign and follow the instructions to avoid damag...

Page 5: ...flow with minimum fluid pulsation and low pump noise Fluid flowing through the pump provides lubrication for moving parts B 1 2 CIG General Description The CIG is a positive displacement internal gea...

Page 6: ...6 B 2 3 CIG Designation B 2 4 2BIC Designation B 3 Labeling B 3 1 CE Nameplate...

Page 7: ...al knowledge to apply generally accepted safety and operational practices which may not be otherwise covered Every effort was made to prepare the text of this manual so that technical information is c...

Page 8: ...ssure monitoring devices and sealing apparatus are installed and operation prior to starting the pump CAUTION Do not operate the pump while the valves in the system are closed o Pumps may not be used...

Page 9: ...valves can be opened or the blockage removed i NOTE Only trained specialized personnel are qualified to perform maintenance which includes but is not limited to o Inspection o Repair o Assembly o Disa...

Page 10: ...on from hot surfaces and hot liquids must be provided by the operator Take care not to drop the pump Pump weights are clearly and durably marked onto the pump surface Read and consider the weight prio...

Page 11: ...p housing WARNING On critical or dangerous equipment provide safety and emergency systems to protect personnel and property from injury due to pump malfunction If pumped liquids are flammable toxic co...

Page 12: ...other cool liquid to the surface If the pump is to be preheated or cooled prior to installation heat or cool the pump to the operating temperature by use of an approved method such as a band heater ba...

Page 13: ...are available Re adjust the packing follower several times through the running in period until the seal is thoroughly seated and the rate of leakage is stable F Operation Shutdown Restart F 1 Heating...

Page 14: ...ing power to driver Shut wire or chain and lock all valves in pump inlet outlet piping If applicable shut off any steam or other fluid supply lines to the pump Visually check equipment frequently for...

Page 15: ...Installation of spare parts should only be performed by trained specialized personnel in conjunction with the appropriate Original Installation Care and Maintenance Instructions H Failure All failures...

Page 16: ...2018 CIRCOR Pumps North America LLC All rights reserved CIRCOR 1710 Airport Road P O Box 5020 Monroe NC USA 28111 5020 Tel 704 289 6511 Website www circorpt com e mail cc circor com...

Reviews: