OPERATING MANUAL
MIG (GMAW) WELDING
5-22
Manual 0-5586
5.17 Setup for PUSH PULL GUN MIG (GMAW) Welding with Gas Shielded Mig
Wire
A. Select MIG mode with the process selection control (refer to Section 4.02.12 for further information).
B. Connect the Mig torch polarity lead to the positive welding terminal (+). If in doubt, consult the electrode wire
manufacturer. Welding current flows from the Power Source via Dinse type terminals. It is essential,however,
that the male plug is inserted and turned securely to achieve a sound electrical connection.
C. Fit the Euro Push-pull Gun to the power source using the front panel EURO torch adaptor (refer also to
Section 5.06 the Tweco Professional Fusion MIG Torch). Connect the push-pull gun 10 pin Remote Control
Plug to the 10 pin Synergic Control Socket on Synchroniser Box. Connect the Synchroniser Box 8 pin
Remote Control Plug to the 8 pin Remote Control Socket on the power source.
D. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode wire
manufacturer. Welding current flows from the Power Source via Dinse type terminals. It is essential,
however, that the male plug is inserted and turned securely to achieve a sound electrical connection.
E. Fit the welding grade shielding gas regulator/flowmeter to the shielding gas cylinder (refer to Section 5.01)
then connect the shielding gas hose from the shielding gas regulator/flowmeter outlet to the quick connect
Shielding Gas Inlet fitting gas on the rear of the Transmig 355i Power Source. Ensure that the shielding
gas hose connection is sufficiently tight at the regulator connection and the quick connect fitting "locks"
into place correctly on the rear of the power source.
F. Refer to the Weld Guide located on the inside of the wirefeed compartment door for further information.
G. Select MIG mode with the process selection control (refer to Section 4.02.12 for further information).
H. In MIG (GMAW/FCAW)Mode Advanced Features Menu Map, select Remote/ Local to P/P. Refer to Section
4.03 for further information.
I. Set the Internal Switch located in the Power Source Wire Drive compartment to <2> P/Pull Gun via 355i
position. Refer to Section 4.02.26 for further information.
!
WARNING
Before connecting the work clamp to the work make sure the mains power supply is
switched off.
Secure the welding grade shielding gas cylinder in an upright position by chaining it to a
suitable stationary support to prevent falling or tipping.
!!
CAUTION
Loose welding terminal connections can cause overheating and result in the male plug being fused in the terminal.
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the Welding Power Source.
!!
CAUTION
Please keep control leads of Push-Pull Gun and Synchroniser Box away from hot torch end or door panel of Transmig 355i
and Transmig 4RX remote wirefeeder.
Summary of Contents for Transmig 355i
Page 8: ...This Page Intentionally Blank ...
Page 14: ...OPERATING MANUAL GENERAL INFORMATION 1 6 Manual 0 5586 This Page Intentionally Blank ...
Page 24: ...OPERATING MANUAL INTRODUCTION 2 10 Manual 0 5586 This Page Intentionally Blank ...
Page 28: ...OPERATING MANUAL INSTALLATION 3 4 Manual 0 5586 This Page Intentionally Blank ...
Page 84: ...OPERATING MANUAL TIG GTAW WELDING 6 10 Manual 0 5586 This Page Intentionally Blank ...
Page 110: ...OPERATING MANUAL KEY SPARE PARTS 9 4 Manual 0 5586 This page intentionally blank ...
Page 112: ...OPERATING MANUAL APPENDIX A 2 Manual 0 5550 This Page Intentionally Blank ...