TRANSTIG 220AC/DC AND 300AC/DC POWER SOURCE
INSTALLATION, OPERATION AND SETUP
3-32
Manual 0-5293
Water Pump Test
Only for water pump with Net Connection interface
• Press and hold the FORWARD button (22).
• Press the WELDING TYPE button (17).
• The Water Cooler (Net Connection type) will run for approximately 30 seconds.
If there is an error, or no pump is connected, the error message
will be displayed after approximately 5 seconds.
A-12050
Figure 3-19: Water Pump Test
3.19 Information Messages
If a message has been displayed, the power source may only function to a limited capacity. The cause of the
condition must be remedied as soon as possible.
Message Code
Note
Cause
Possible Remedy
Mains Supply Under
Voltage
Mains Supply Voltage is
too low
Check Mains Supply
Voltage
Fans
Fan Fault
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source.
PFC Input Stage
PFC Input Stage is Faulty Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source.
Summary of Contents for A-12030
Page 6: ......