Hardware Installation Manual

MAN-0143-001

- Revision A

March 20, 2009
Copyright Ciena

®

 Corporation

CN 3960

®

Service Delivery Switch

Summary of Contents for 170-3960-900

Page 1: ...Ciena Confidential and Proprietary Hardware Installation Manual MAN 0143 001 Revision A March 20 2009 Copyright Ciena Corporation CN 3960 Service Delivery Switch...

Page 2: ...e or retrieval system without express written permission of the Ciena Corporation Security Ciena cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unaut...

Page 3: ...ns 7 Resets 9 Environmental Control 10 Grounding 11 Interfaces 12 Default Configuration 16 Local Management Port 16 LOG Server 16 Port Settings 16 VLANs 16 Software Overview 17 SNMP 17 Device Manager...

Page 4: ...e CN 3960 35 Initial Configuration 36 Maintenance 37 Appendix A LED Overview 39 Unit Status LEDs 40 10 Gigabit Ethernet Port LEDs 41 10 100 1000 Mbps Port LEDs 42 Local Management Port LEDs 43 Appendi...

Page 5: ...on is intended for users such as network technicians and system administrators who will installthesedevicesintoaservicesdistributioninfrastructure Itassumesthattheintendeduserspossess basic knowledge...

Page 6: ...ormationso the usercanavoidequipment damage or data loss NOTE This symbol is used to highlight additional information Important Safety Information WARNING This equipment is to be installed in a Restri...

Page 7: ...y to deliver complete integrated service offerings from a single provider or multiple providers The SDS devices incorporate advanced QoS capabilities flexibility through pluggable optics superior mult...

Page 8: ...e providers networks or the PSTN can be achieved using other solutions that are available within the Ciena Corporation family of products The front panel of the chassis also provides status LEDs for t...

Page 9: ...is designed so that the power cabling is located on the rear of the chassis While all the interface cabling is located on the faceplate of the chassis NOTE To provide sufficient clearance for cabling...

Page 10: ...3960 can be mounted in either front or mid mount position The orientation of the bracket and the choice of mounting holes used dictates the final placement of the unit within the frame The following p...

Page 11: ...3 The second power supply bay must be covered with a filler plate The filler plate is necessary for safety and to ensure proper airflow within the CN 3960 Figure 1 3 Rear of CN 3960 When two power su...

Page 12: ...upply fan should fail or another problem occurs with the power supply an alarm is raised and an SNMP trap is sent If the power supply has been disabled an LED indication will also occur showing the de...

Page 13: ...reset button is located to the left of the management port on the far right of the chassis Figure 1 4 shows the location of the reset button Figure 1 4 Location of Reset Button There are two different...

Page 14: ...e returns to the supported operating temperature range the unit will automatically restart and resume service Fans and Airflow The CN 3960 has three fans to provide adequate air flow The fans draw air...

Page 15: ...ly attached when the CN 3960 is installed Supplemental ground There are two holes and screws located on the left side of the back of the chassis for connecting a grounding lug to the chassis See the I...

Page 16: ...ured as either NNI or UNI ports Two of the 10 Gigabit Ethernet ports support enhanced features That functionality is controlled by the software provisioning and is not described in this manual For pro...

Page 17: ...status LEDs Unsupported optics will generate an LED indication and will not function The list of supported SFPs is included in the following tables Table 1 5 Supported SFP Optics Dual Fiber on page 1...

Page 18: ...length XCVR 080D43 1000BASE CWDM CWDM 80 km 1430 nm XCVR 080D45 1000BASE CWDM CWDM 80 km 1450 nm XCVR 080D47 1000BASE CWDM CWDM 80 km 1470 nm XCVR 080D49 1000BASE CWDM CWDM 80 km 1490 nm XCVR 080D51 1...

Page 19: ...a terminal or a PC to the device for out of band management The EIA 232 port connector uses a standard DB 9 connector that follows standard DTE wiring pin assignment A null modem cable should be used...

Page 20: ...ting a PC directly to the local management port a straight through or crossover cable can be used LOG Server The LOG server is used to archive the system logs from the node The LOG server has the foll...

Page 21: ...MP RFC 1157 MIB II RFC 1213 Bridge MIB RFC 1493 Ethernet MIB RFC 1643 4 group RMON RFC 1757 IP Forwarding Table MIBs RFC 2096 Multicast Routing MIBs Device Manager The SDS switches are managed directl...

Page 22: ...r or delay Valuable usage statistics are also collected VLANs are identified using 802 1Q tags As needed each VLAN can carry multiple services or one single service As a subscriber signs up for a serv...

Page 23: ...will also need to supply Faceplate cabling to suit your installation Grounding lug and grounding wire see the Supplemental ground section on page 11 for specifications Power wiring DC installations ra...

Page 24: ...on page 13 for a summary Various SFP Dual Fiber See Table 1 5 on page 13 for a summary Various SFP CWDM See Table 1 7 on page 14 for a summary Various XFP See Table 1 4 on page 12 for a summary Replac...

Page 25: ...d to the back of the chassis on the left hand side Mounting brackets for 19 inch rack and screws 2 brackets and 4 screws If the unit is damaged or if any of the above items are missing please contact...

Page 26: ...ppendix D Translation of Warnings and Cautions on page 49 for the translated text WARNING Read all installation instructions before connecting a CN 3960 device to a power source WARNING Before working...

Page 27: ...ounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety Mount the equipment rack...

Page 28: ...evice to the rack with customer provided rack screws 4 Connect the device to supplemental ground using the Installing Supplemental Ground section on page 25 5 Install power to the CN 3960 using one of...

Page 29: ...ewdriver and the two screws supplied connect a copper conductor ground wire to the ground connectors on the far left of the rear of the chassis Figure 2 1 shows a grounding lug attached to the chassis...

Page 30: ...d to relieve the cord weight from the connector This is accomplished by using a cable tie to attach the power cord to the handle of the power supply Procedure for installing a cable tie to restrain th...

Page 31: ...ghten the single captive hold down screw 5 Do one of the following If this is aninstallation with a single power supply verify that the second power supply slot is covered with a cover plate Proceed t...

Page 32: ...ply to be removed and replaced while the remaining supply will compensate to maintain uninterrupted system operation However care must be taken to avoid personal injury when removing a power supply wh...

Page 33: ...m 18 gauge wire WARNING Before performing the procedure ensure that all power is off to the DC circuit Locate the circuit and switch it to the OFF position Tape the circuit breaker switch handle in th...

Page 34: ...and PS B if installed and tighten the set screws if present NOTE Separate breakers should be used for PS A and P SB This ensures that power can be removed from one power supply so that it can be repl...

Page 35: ...ircuit 1 Remove power from the DC circuit supplying power to the device 2 If the power cable is attached to the power supply using a cable tie use cutters to remove the secured power cable from the ha...

Page 36: ...d into each available port and can be hot swapped Figure 2 4 shows a typical pluggable optic module and its parts Figure 2 4 Pluggable Optic Modules The installation procedure is the same for both SFP...

Page 37: ...may be carefully reformed with needle nose pliers 3 Gently pull on the optic to make sure that it has seated properly WARNING Optic operation should be verified by observing the status LEDs Do not loo...

Page 38: ...port or install the removed optic into a different port Interface Cabling This guide assumes that the site s data cables have been properly installed in a centrally wired distribution configuration W...

Page 39: ...time Ciena recommends that cables be connected in the following order Fiber cables first Shielded Cat 5e cables last In order for two devices to communicate properly the transmit ports on the first d...

Page 40: ...the use of Shielded Cat 5e cable or better To install a Shielded Cat 5e cable insert the connector into the port on the device until you hear a clicking sound Insertthe tail end of the cable into the...

Page 41: ...remainpoweredforallthesemaintenance tasks There is no requirement to remove power from the unit before performing these types of routine maintenance The following are examples of service impacting mai...

Page 42: ...38 CN 3960 Hardware Installation Guide INSTALLATION MAINTENANCE...

Page 43: ...are accessible from the faceplate of the unit With the exception of the EIA 232 Console port all the interfaces have integrated LEDs which provide status information for the port Figure 1 1 on page 5...

Page 44: ...Off Power Supply B is active Power Supply inactive or not present STAT Off Solid Green Blinking Green System is not operating normally Indicates status normal system ready System is initializing and...

Page 45: ...has a single LED The LED is located to the left of the port and indicates port status Figure A 2 10 Gigabit Ethernet Port LEDs Table A 2 10 Gigabit Ethernet Port LED LED Indication Description LNK ACT...

Page 46: ...he RJ 45 connectors for the port and indicate port status Figure A 3 10 100 1000 Mbps Port LEDs Table A 3 10 100 1000 Mbps Port LEDs LED Indication Description LNK ACT Off Green Blinking Green The por...

Page 47: ...tom of the port and indicate port status Figure A 4 Local Management Port LEDs Table A 4 Local Management Port LEDs LED Indication Description LNK ACT Off Green Blinking Green The port is not operatio...

Page 48: ...44 CN 3960 Hardware Installation Guide LOCAL MANAGEMENT PORT LEDS...

Page 49: ...240 VAC 50 60 Hz 3 0 2 4 A 48 to 60 VDC 4 0 A Connector Types NNI UNI Ports 10 Gigabit UNI Ports 10 100 1000 Mbps Local Management Port Console Port XFP optics SFP optics or RJ 45 RJ 45 DB 9 Physical...

Page 50: ...46 CN 3960 Hardware Installation Guide...

Page 51: ...NZS 60950 1 2003 Australia and New Zealand CAN CSA 22 2 No 60950 1 06 Canada CB report based on IECEE all national deviations EN 60950 1 2006 EU IEC 60950 1 Second Edition 2005 12 International NOM 01...

Page 52: ...ena Eine gezeichnete Kopie der EU Konformit tserkl rung ist bei der Hauptgesch ftsstelle von Ciena erh ltlich FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to t...

Page 53: ...ations to the following languages are available within this chapter French German French Cette section comporte une traduction des avertissements et mises en garde contenus dans le guide d installatio...

Page 54: ...to be installed and maintained by qualified service personnel only See page 1 for the original warning AVERTISSEMENT Cet quipement doit tre install et entretenu uniquement par unpersonneldeservice qua...

Page 55: ...tzwerks des Anbieters gedacht Durch andere L sungen aus dem Produktsortiment der Ciena Corporation sind jedoch auch Verbindungen zu den Netzwerken anderer Anbieter oder zum PSTN m glich Die urspr ngli...

Page 56: ...t be properly attached when the CN 3960 is installed See page 11 for the original warning AVERTISSEMENT Dans la version en courant continu la mise la terre pour la s curit lectrique est assur e par le...

Page 57: ...nde mit den Anschlussklemmen verschmelzen Die urspr ngliche Warnung finden Sie auf Seite 22 WARNING Do not work on the system or connect or disconnect cables during periods of lightning activity See...

Page 58: ...arning AVERTISSEMENT Pour viter toute blessure corporelle pendant les op rations de montage d entretien ou de r paration de cette unit en baie il convient de prendre des pr cautions sp ciales afin de...

Page 59: ...digungen des Ger ts kommen Die urspr ngliche Warnung finden Sie auf Seite 23 WARNING When installing the unit ensure that the wiring meets the local electrical code See page 23 for the original warni...

Page 60: ...e tableau de contr le qui alimente le circuit en courant continu l aide d un ruban adh sif bloquez le bouton de l interrupteur du disjoncteur en position OFF afin d emp cher la fermeture accidentelle...

Page 61: ...Source UL 60950 Information Technology equipment and European norms EN60825 1 and EN60825 2 Failure to use laser transceivers which meet these standards could result in eye damage to users or service...

Page 62: ...ible radiation may be emitted from the aperture of the port when no fiber cable is connected avoid exposure to radiation and do not stare into open apertures See page 34 for the original warning AVERT...

Page 63: ...g the Reset button See page 36 for the original warning ATTENTION La d finition de l adresse IP ou du masque de sous r seau exige une pr caution particuli re dans la mesure o les nouvelles valeurs pre...

Page 64: ...60 CN 3960 Hardware Installation Guide T RANSLATIONS...

Page 65: ...iena Customer Support using any of the following methods Address Ciena Corporation 1201 Winterson Road Linthicum MD 21090 Internet Site Additional contactinformationand general productsupport canbe ac...

Page 66: ...nd Fax For technical support for Ciena Corporation products contact the Customer Support by phone or fax North America 800 Ciena24 1 800 243 6224 or 1 410 865 4961 EMEA 800 Ciena24 7 800 243 6224 7 or...

Page 67: ...em SAOS and programmable network devices Channel Stream isacollectionofuser defined multicast groups that are flooded to all ports in a VLAN bringing these streams far down into the network before the...

Page 68: ...to 1 75 inches 4 45 cm RSTP Rapid Spanning Tree Protocol is a Layer 2 link management protocol defined in IEEE 802 1W that provides network path redundancy while preventing topology loops RSTP improv...

Page 69: ...k is a logical element used to group resources that have a common set of requirements together regardless of where they are located physically VPLS Virtual Private LAN Service is a class of VPN thatal...

Page 70: ...CN 3960 Hardware Installation Guide...

Page 71: ......

Page 72: ...Copyright 2009 Ciena Corporation...

Reviews: