![cias IB-SERVER Installation Handbook Download Page 19](http://html1.mh-extra.com/html/cias/ib-server/ib-server_installation-handbook_2606594019.webp)
©
CIAS Elettronica S.r.l.
Ed 1.2
4.3 Hour Sync
The sync of the clock of each device is automatically done every midnight and every time there is
one time set up of any device.
4.3 Tamper Contact
Connect to terminal strip “
TAMPER
” pins the two conductors coming from the open contact ("reed"
type) protecting the central from the metallic container opening.
This contact opening cause the tamper relay, present on the circuit, activation (OUT 1), see figure
on page 18.
5. MAINTENANCE AND SERVICE
5.1 Fault location
Fault
Possible reason
Possible solution
Wrong connections
Check connections
Device / Barrier setting N° is
wrong
Check the IB-Server setting
IB-Server not configured
Carry out the Auto-configuration
procedure
Not any status is detected by the
IB-Island
IB-Server fault
Substitute the IB-Server
Wrong connections
Check connections
Not any status is detected by
one IB-Island
Device / Barrier setting N° is
wrong
Check the IB-Server setting
Connection to the detector wrong Check the connections
IB-Island detect only No Answer
status
Detector Address wrong
Check that the IB-Island Address
is the same of the detector
address
Installation Handbook
Page
18 of
18
IB-SERVER
Summary of Contents for IB-SERVER
Page 1: ......