3. TRANSMITTER
Please see the figure below with regards to the wiring to be carried out on the transmitting
module:
Terminal 1 = Positive 13.8 Vdc (Power)
Terminal 2 = Negative GND (Power)
Terminal 3 = Not used
Terminal 4 = Not used
Terminal 5 = Not used
Terminal 6 = NC Tamper Contact
Terminal 7 = NC Tamper Contact
Terminal 8 = Not used
Terminal 9 = Not used
3.1. Connections
The Tamper acts on front cover closing and opening.
3.2. Dip Switch Functions
Transmission channel selection is made via the dip switch located on the right side of the
NEWTON-L module.