CHUNDA ISCDOSA4205 Hardware Manual Download Page 1

 

 ISCDOSA4205 

 

Standalone Access Controller 

Hardware Manual 

Version 1.0 

 

 

 

Summary of Contents for ISCDOSA4205

Page 1: ...ISCDOSA4205 Standalone Access Controller Hardware Manual Version 1 0...

Page 2: ...ction 13 3 2 5 Slave Reader Connection 15 3 2 6 Power Supply Connection 16 Chapter 4 Installations 17 4 1 Hardware Setup 17 4 2 Communication Interface Connection 18 4 3 ISCDOSE4002 Wire Diagram 19 Ch...

Page 3: ...rd No 43 5 2 23 Mifare Length of card No 44 5 2 24 Compress Mifare Card No 45 5 2 25 Set Key Value 46 5 2 26 Read Block Mode 47 5 2 27 Set Master Code 48 5 2 28 Set Disarm Card Code 49 5 2 29 Set Dure...

Page 4: ...CHUNDA 4 ISCDOSA4205 Hardware manual Chapter 1 Product Overview 1 1 Package Contents Controller x 1 Base x 1 Quick Start Guide x 1 Screw x 3 Cable x 1...

Page 5: ...onforms to ISO 14443A supporting Mifare card Unique ID or Block reading format supported and programmable key value Duress card code setting When door opened in the emergency controller will send sign...

Page 6: ...5 Input Ports 3 Sensors Door Sensor x 1 Exit switch x 1 Tamper Switch x 1 Output Ports Built in Relay x 1 Door Lock or Bell O C Output x 2 Door Lock Alarm external ISCDOSE4002 Keypad 13 Key 0 9 Bell S...

Page 7: ...CHUNDA 7 ISCDOSA4205 Hardware manual Chapter 2 Physical Dimension 2 1 Dimension Scale mm...

Page 8: ...ly B Numerical Keypad 0 9 Numeric key Cancel Enter C Bell Bell Function key Request Bell function should select mode 1 and activate by HAMS Relay Active as below Relay 0 signifies Controller relay Rel...

Page 9: ...CHUNDA 9 ISCDOSA4205 Hardware manual Chapter 3 System Configuration Wire Connections 3 1 System Configuration...

Page 10: ...A 10 ISCDOSA4205 Hardware manual 3 2 Wire Connections 3 2 1 Controller Terminal Introduction A Case Sensor B IDSetting Kindly refer to Chapter5 1 C Contact Kindly refer to Chapter 3 2 D JP1 Built in R...

Page 11: ...CHUNDA 11 ISCDOSA4205 Hardware manual 3 2 2 Alarm Connection With ISCDOSE4002 for digital output...

Page 12: ...CHUNDA 12 ISCDOSA4205 Hardware manual 3 2 3 Electronic Lock Setup Without ISCDOSE4002 for digital output With ISCDOSE4002 for digital output...

Page 13: ...CHUNDA 13 ISCDOSA4205 Hardware manual 3 2 4 Exit Button Door Sensor Connection Without ISCDOSE4002 for digital output...

Page 14: ...CHUNDA 14 ISCDOSA4205 Hardware manual With ISCDOSE4002 for digital output...

Page 15: ...CHUNDA 15 ISCDOSA4205 Hardware manual 3 2 5 Slave Reader Connection...

Page 16: ...CHUNDA 16 ISCDOSA4205 Hardware manual 3 2 6 Power Supply Connection Note To avoid interference self detection of sensitive keypad please do not touch keypad when input power...

Page 17: ...over tighten the back base screws during installation to prevent distortion A Mount the base base onto the wall or other desired location B Connect the wires in accordance with the wiring instruction...

Page 18: ...CHUNDA 18 ISCDOSA4205 Hardware manual 4 2 Communication Interface Connection...

Page 19: ...CHUNDA 19 ISCDOSA4205 Hardware manual 4 3 ISCDOSE4002 Wire Diagram...

Page 20: ...CHUNDA 20 ISCDOSA4205 Hardware manual Chapter 5 Setting 5 1 ID Setting...

Page 21: ...authorized modification on the settings Upon entering command mode Controller beeps five times and waits for the command input PWR LED flashes red light After entering command controller beeps once In...

Page 22: ...r can be 10 digits or less while in compressed or shared memory card number should be exactly 10 digits If you don t want to add password simply press Passwords are not allowed under shared mode Card...

Page 23: ...CDOSA4205 Hardware manual 5 2 2 Delete a Card Number Command Code 02 Deletes a single card number and also removes its access authorization Enter 02 Input Card Number Completed Master Card Code Defaul...

Page 24: ...Command Code 03 Deletes all valid card numbers Deleting all card numbers will remove all access authorizations and requires user to input new card numbers Kindly take caution in performing this operat...

Page 25: ...performed under shared memory Command Code 04 Successive Addition of Card Numbers ISCDOSA4205 allows user to add card numbers in an efficient manner by simply entering the index card number and the to...

Page 26: ...ard Numbers This command is only allowed to be performed under shared memory Command Code 05 Successive deletion of card numbers All access authorizations will be deleted as well Enter 05 Initial Card...

Page 27: ...et the door relay status 0 is Pulse 1 is Toggle Pulse Door relay will return to original position within the time user set Toggle Door relay will not return to original position until alarm relay has...

Page 28: ...door opening time upon valid card swipe or exit button request Default time is 4 sec Time duration can be set from 1 to 600 sec System ignores parameters set to 0 or greater than 600 sec default time...

Page 29: ...oor sensor detection time has been set system will monitor door s status If the allotted door open time has expired controller beeps every 0 5 sec The door has to be closed for the controller to termi...

Page 30: ...r Settings Command Code 12 Enter 1 9999 sec to set conditional unlock door settings The door can remain open until the allotted time If parameter value is set to 0 then conditional unlock door functio...

Page 31: ...ss Command Code 13 Allows user to set the compare valid address Compare Valid address Compare valid code Index 1 X16 Compare valid code length 0 Select All Only support standard card mode Enter 13 Com...

Page 32: ...vates alarm on door prop 0 1 Controller beeps on door prop 1 Door Forced Detection 0 Enable Forced Door Open Detection 0 64 Disable Forced Door Open Detection 64 Door Prop 0 Enable Door Prop Detection...

Page 33: ...ion Table Function Code Action Value Card Swipe Identification 0 Disable Card Swipe 0 16 Enable Card Swipe 16 Keypad Tones 0 Keypad Tones OFF 0 32 Keypad Tones ON 32 Enable Case Sensor 0 Disable Case...

Page 34: ...5 2 13 Reswipe Card Check Time Command Code 22 Enables reswipe card check time This function restricts a card to be swiped twice under a specified time Enter 22 Duration Master Card Code Default 3019...

Page 35: ...the table below for the list of settings Function Table Function Code Action Value Exit Button NO NC 0 Exit Button NC 0 1 Exit Button NO 1 Door Sensor NO NC 0 Door Sensor NO 0 4 Door Sensor NC 4 Exam...

Page 36: ...dware manual 5 2 15 Access Granted for Master Code Command Code 24 Sets valid access authorization to Master Code Door opens when Master Code is entered Enter 24 Value Master Card Code Default 3019100...

Page 37: ...displayed on the LCD display Date format is yy mm dd ww where yy stands for year 00 63 mm stands for month 01 12 dd stands for date 01 31 and ww stands for week 01 07 01for Monday 07 represents Sunda...

Page 38: ...5 2 17 Set Time Command Code 26 Sets displayed time on the LCD display Time format is hh mm ss where hh represents hour 00 23 mm for minutes 00 59 and ss for seconds 00 59 Enter 26 hh mm ss Master Ca...

Page 39: ...set 0 keypads are disabled when parameter is set to 1 keypads are enabled Note Do not disable keypad when you don t have the Master Card Master Code is required to enter command mode hence disabling...

Page 40: ...manual 5 2 19 Save Invalid Card No Command Cod 31 Allows user to save invalid card number To record invalid card numbers set parameter to 1 to ignore set to 0 Enter 31 Value Master Card Code Default 3...

Page 41: ...2 20 Mifare Card Reading Format Command Code 80 Allows user to set the reading format of Mifare cards Set 0 to read serial number 1 to read Block Key A and 2 to read Block Key B Enter 80 Value Master...

Page 42: ...CHUNDA 42 ISCDOSA4205 Hardware manual 5 2 21 Mifare Read Block Settings Command Code 81 Selects the block to read within a Mifare Card 0 63 Enter 81 Value Master Card Code Default 30191000 P Completed...

Page 43: ...ss of card number to be read 1 15 ISCDOSA4205 will retrieve card number starting from the index address that the user has set Note Please set Command code 86 in Fixed Length before set Mifare Index of...

Page 44: ...ngth set to 05 ISCDOSA4205 will start with the 2nd digit and count five numbers This will be the card number that is going to be compared with the database Example For card number 12345678 the 5 digit...

Page 45: ...CDOSA4205 Hardware manual 5 2 24 Compress Mifare Card No Command Code 84 Allows user to compress Mifare Card No 0 Do not compress 1 Compress Enter 84 Value Master Card Code Default 30191000 P Complete...

Page 46: ...a card Kindly set the key value used by the cardholder For key value please refer to the table below Function Table Input Value Key Value Input Value Key Value 30 0 41 A 31 1 42 B 32 2 43 C 33 3 44 D...

Page 47: ...Hardware manual 5 2 26 Read Block Mode Command Code 86 Set the read block mode Support v2 01above 0 Variant Length 1 Fixed Length Set digits length in command 83 Enter 86 Value Master Card Code Defaul...

Page 48: ...master code Default Master Code is 30191000 To change kindly follow the instructions below and input the new 10 digit master code Whenever a device initialization has been performed master code will b...

Page 49: ...m card code Default disarm card code is 0000 To change kindly follow the instructions below and input the new 10 digit or less disarm code card Whenever a device initialization has been performed disa...

Page 50: ...e duress card code Default value is 1190 To change kindly follow the instructions below and input the new 10 digit or less duress code card Whenever a device initialization has been performed duress c...

Page 51: ...ompressed memory supports 1400 compressed card nos with password and 1800 event records iii Shared memory supports 65536 card nos without password and 1800 event records Under compressed and shared me...

Page 52: ...e 94 Allows user to change the access mode swipe card only swipe card or key in card No swipe card or key in card No password This function is only applicable when ISCDOSA4205 is used as an access con...

Page 53: ...valid but does not save card records Random Mode2 Mifare Key is correct and card number has been written to block The card woll be valid and save card records When you add card no by command1 and sele...

Page 54: ...d 0 Do not need check password 0 1 Check Password 1 Interface Select value only 16 W26 8 Digits 16 32 W26 10Digits 32 48 W34 10 Digits 48 Disable Anti 0 Enable Anti 0 4 Disable Anti 4 Example Slave re...

Page 55: ...CHUNDA 55 ISCDOSA4205 Hardware manual 5 2 34 Relay Mode Command Code 97 Allows user to change the relaty mode 0 Door Relay 1 Bell Enter 97 Value Master Card Code Default 30191000 P Completed...

Page 56: ...ngs master code and restores all parameters to default settings After performing this function card number and parameter should be reset Initialization should be performed only when the ff occurs On t...

Page 57: ...Power 2 Reader beeps after 1 sec indicating startup completed 3 Green LED blinks 4 Press Exit Button to activate Door Relay and Electronic Lock activates for 4 sec 5 Reader beeps twice short beeps for...

Page 58: ...s check if you are reading the right block and key Q3 Unable to enter command mode using Master Code A Master code is required to enter the command code hence initialization has to be performed Kindly...

Page 59: ...essive deletion of card no For shared mode only MASTER 05 Initial Card No Total no of cards Completed 09 Door Relay Mode Default 400 MASTER 09 Summation of the value listed below Completed 0 Pulse Doo...

Page 60: ...le 0 to Enable 21 Advanced Settings 2 For more information about this command click on the command code MASTER 21 Summation of the value listed below Completed 16 Card Swipe Enable 0 to Disable 32 Key...

Page 61: ...alue Completed Address 1 15 Default is 1 83 Mifare Length of card No For Mifare Only MASTER 83 Value Completed 0 Select 1 10 84 Compress Mifare Card No For Mifare Only MASTER 84 Value Completed 0 No 1...

Page 62: ...e2 Mifare Key is correct and card number has been written to block The card will be valid and save card records When you add card no by command1 and select Random Mode2 the cards will become blacklist...

Page 63: ...re shielded twisted pair wire 20 22 AWG 25M RS 485 Cable 4 core shielded twisted pair wire 20 22 AWG 800 M Upgrade the cable specification according to transmission distance Upgrade the cable specific...

Page 64: ...on of any part of the product This warranty does not cover damage due to improper operation or maintenance connection to improper equipment or attempted repair by anyone other than In no event shall m...

Reviews: