Chronomite CMT-1.3 Installation And Operation Instructions Manual Download Page 1

TABLE OF CONTENTS

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Technical Description,  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Plumbing Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Temperature & Pressure Relief Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Filling the Water Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Instructions for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Maintenance Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13
Troubhshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Schematic Disassembly & Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

?

1/2” NPS Flex Hose (2) 

?

Carpenters level 

?

Adjustable Wrench

?

Flat Head Screwdriver

?

Phillips Head Screwdriver

?

Teflon Tape or Pipe Dope

REQUIRED ITEMS FOR INSTALLATION NOT SUPPLIED

Chronomite Laboratories is a Member of Morris Group International™

ELECTRIC TANK WATER HEATER - POINT OF USE

ELECTRIC MINI TANK - 
WATER HEATERS 

INSTALLATION AND OPERATION 
INSTRUCTIONS
(CMT-1.3, CMT-2.5, CMT-4.0 & CMT-6.0)

COMPLIES 

WITH

3100-010-001
10/17 REV 1

Acorn Engineering Company™ assumes no 
responsibility for use of void or superseded data. 
© Copyright Acorn Engineering, City of Industry,
CA  Member of  Morris Group International.
Please visit 

 

for most 

current specifications.

www.chronomite.com

Member of

CHRONOMITE

 

Water Heaters 

17451 Hurley St.

City of Industry, CA

91744 U.S.A.

Phone 800-447-4962

626-937-4270

w w w. c h r o n o m i t e . c o m

 

Federal
Public Law
111-380 
(No Lead)

CMT-ST70
Tempering Valve
Optionally available

CMT-1.3, CMT-2.5, CMT-4.0 & CMT-6.0

Summary of Contents for CMT-1.3

Page 1: ...UPPLIED Chronomite Laboratories is a Member of Morris Group International ELECTRIC TANK WATER HEATER POINT OF USE ELECTRIC MINI TANK WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS CMT 1 3 CMT 2...

Page 2: ...ced only by qualified service personnel Contact nearest authorized service facility for examination repair or adjustment 9 If the unit is installed in an area where there is a potential for freezing t...

Page 3: ...1 3 2 5 4 0 6 0 Voltage Vac 110 120 110 120 110 120 110 120 Power at 120 VAC Watts 1440 1440 1440 1440 Max Water Pressure PSI 150 150 150 150 Weight empty LBS 12 5 20 24 26 Amperage Amps 12 12 12 12 P...

Page 4: ...4 0 CMT 6 0 A inch 12 1 2 14 1 2 19 1 4 18 B inch 11 11 3 4 11 3 4 15 3 4 C inch 10 10 3 8 10 3 8 15 1 2 ELECTRIC TANK WATER HEATER POINT OF USE E N L B C A Indicator Light Thermostat Heating Element...

Page 5: ...educe the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the nearest and most distant sink being served by this water heater before...

Page 6: ...ng slots Confirm your water piping orientation hot and cold before wall mounting Only install in vertical position Heater can sit on the floor Confirm water piping orientation before finalizing on flo...

Page 7: ...P valve into the threaded opening at the top of the water heater using heavy duty Teflon tape Orient the discharge tubing so that any discharge from the valve will exit within 6 inches above or at an...

Page 8: ...The expansion tank must have a minimum capacity of 1 5 U S gallons for every 50 gallons of stored water 2 Install a 125 PSI pressure relief valve in the cold water supply line Make sure the discharge...

Page 9: ...ker into the master panel The Chronomite water heater was manufactured and wired in accordance with UL requirements The water heater is equipped with an overheat limiting device with a manual reset Al...

Page 10: ...be illuminated The temperature adjusting knob will increase the temperature by turning the knob clockwise and decrease the water temperature by turning the knob counter clockwise When not being used...

Page 11: ...faucet 5 Disconnect the water heater from both the hot and cold water connections 6 If possible siphon out remaining water 7 Carefully detach the water heater from the wall 8 Tilt the water heater to...

Page 12: ...rmostat 1 Turn off the power switch and unplug the water heater from the electric outlet 2 Drain and remove the water heater see page 11 3 Remove six screws retaining the bottom panel of the water hea...

Page 13: ...high temperature water inside the heater Do not tamper with the reset button to override overheating shut down 1 Turn off the power switch and unplug the water heater from the electric outlet 2 Drain...

Page 14: ...cator light not on 1 If the light does not come on but water gets hot check for faulty indicator light 2 Check reset button follow steps from previous section Problem Brown water 1 Brown or rusty wate...

Page 15: ...Circle 1 7 Bottom Cover 1 26 Power Cord Sheath 1 8 Indicate Light Cover 1 27 Power Cord Sheath Press 1 9 Power Indicate Light 1 28 Cross Screw 2 10 Support 1 2 29 Connect Plate 1 11 Support 2 2 30 Cr...

Page 16: ...nstalled with improper installation materials In addition the water heater or any of its component parts have been subject to misuse neglect alteration or accident and the water heater has not been in...

Reviews: