07/2020
Corona II
– LED Line Scan Illumination
PMA_CHR_CD40069_R05_Manual_Corona-II_XLC4
32
5.2.4 Cabling and operating Corona II with length > 680 mm
Corona II longer than 680 mm are set up with different segments to length up to 1360 mm.
•
A single XLC4 controller can serve four channels, so two controllers are needed.
•
Both segments are equipped with its own temperature sensor and identification chip.
Both chips will have the same serial number, but they have the individual numbers of
channels saved.
•
Each Corona II has two separate cables to be connected to two different XLC4
controllers.
•
In the XLC4 commander the user must set up two connections with two tabs to control
the two XLC4 separately.
•
Cable lengths start at the fixing of the cable at the housing. If a cable is guided to one
side, take care of the effective cable length of the second cable starting at the center
of the module.
850 mm
1020 mm
Number of channels
Number of channels
Segment 1
2
Segment 1
3
Segment 2
3
Segment 2
3
1190 mm
1360 mm
Number of channels
Number of channels
Segment 1
3
Segment 1
4
Segment 2
4
Segment 2
4
Corona
XLC4
XLC4
Corona
XLC4
XLC4
Corona
XLC4
XLC4
Corona
XLC4
XLC4