![chromasens allPIXA SWIR CD40199 Manual Download Page 33](http://html1.mh-extra.com/html/chromasens/allpixa-swir-cd40199/allpixa-swir-cd40199_manual_2605693033.webp)
PMA_CHR_CD40199_R01_allPIXA_SWIR_GigE_User_Manual.docx
33
7
Camera system set-up
7.1 Installing the camera
Prepare the general setup:
1
Prepare the camera and lens
•
Select the correct lens and accessories to operate your camera in the desired
environment. (For more information about available accessories, see section 9.3.)
•
Install the lens and adapters correctly.
2
Prepare the right cabling for your application
•
The allPIXA SWIR connectors are described in section 5.1.
•
Connection to the PC: The allPIXA SWIR can be connected with a
Cat-5e, Cat-6 or better S/STP Gigabit Ethernet cable with lengths of up to 100 m.
See section 5.6.3.
•
Connect the camera to a power supply (12-24 VDC +/- 10 %, typically 6 W),
see section 5.6.
3
Install and configure the network adapter on your PC
•
See GCT manual.
4
Adjust the focusing point of your illumination unit and position it correctly.
•
Refer to the manual of the illumination manufacturer for proper installation of the
illumination.
•
Make sure that the illumination is positioned correctly to illuminate the scanning area.
5
Mechanically install the camera in your machine
•
Refer to sections 5.4 and 5.5 for details.
•
Make sure that the camera is positioned correctly
The sensor line should be adjusted horizontally to the transport direction and the
camera should look perpendicular to the inspection area.
•
Make sure that you have the correct object-to-sensor distance
The sensor line is positioned 17.526 mm (optical photosensitive surface) behind the
front surface of the allPIXA SWIR camera (C-Mount standard).