![chromasens allPIXA pro Manual Download Page 182](http://html1.mh-extra.com/html/chromasens/allpixa-pro/allpixa-pro_manual_2605692182.webp)
Chromasens CD40127_R02 allPIXA_pro_User Manual.docx
182
If you use
the parameter “Scan line after stop”, the setup deals with this issue:
Sets a suitable value for the parameter
Scan line after stop
, for example 300 lines
Reduces the value of
Image start delay
by half of the value of
Scan lines after stop
, for
example original value of 1000 lines
– (300 lines / 2) = 850 lines
9.9.3 Stop after maximum number of lines
Name
Name
Stop after max. scan lines
Function
Stops the image if no ending edge or signal of the frame trigger is detected
after the given “maximum number of lines”.
Channels
All
Unit
Bool
Dependency
Only available if
Use start and stop condition
is selected at
Triggered
frame scan
Notes
Maximum numbers of scan lines
must be set to a reasonable value.
Camera
Value
Lower limit
All
0
Off
Upper limit
All
1
On