![chromasens allPIXA pro Manual Download Page 152](http://html1.mh-extra.com/html/chromasens/allpixa-pro/allpixa-pro_manual_2605692152.webp)
Chromasens CD40127_R02 allPIXA_pro_User Manual.docx
152
9
Camera parameters
The camera parameters are arranged according the same order as listed in the CST software.
In this part of the manual the parameters are described “as they are”. For a description how to
setup the camera, see section 8
”.
The visibility of the parameters is defined by the specified
User level
in CST. For more
information about which user level is required to modify certain parameters, see section 9.19.
For an overview of the camera parameters and their general functions on the CST user
interface, see section 6.2.
9.1 Integration time parameters
9.1.1 Integration time
Name
Name
Integration time
Function
Sets the integration time in microseconds to the camera
Unit
Float
Step:
0.001
Linear
Dependency
None
Notes
These
are
the
minimum
integration
times
for
the
camera.
The speed could additionally be throttled by Camera Link parameters!
For more information, see section 9.11.4.
Camera:
Value CST:
Lower limit
4k
19,68 µs
5K
24,48 µs
6000
29,14 µs
7.3k
33,65 µs
Upper limit
All
9.25 ms
9.1.2 Use line period
Name
Name
Use Line Period
Function
Activates the function for independent control of integration time and line
period time.
Channels
All
Unit
Bool
Dependency
Camera must be in free-running mode; the Enable encoder check box must be
cleared.
Notes
Camera:
Value CST
Lower limit
All
Off
Upper limit
All
On